AC-Check
11
EN
Please be aware that even if a visual signal is not displayed,
voltage may still be present. Differences in the design of the
connection socket or the nature of the insulation (thickness
and type) can affect functionality. Voltage cannot be detected
behind panels and metal covers.
!
5
Battery lamp
To switch on the battery lamp, press and hold down button 4.
The light switches itself off automatically as soon as the button
is released.
Technical data
Indicator LED, acoustic signal
Voltage range 5 V/AC ... 1000 V/AC
Overvoltage category
CAT III - 1000V (non-condensing)
Pollution degree 2
Power supply 2 x 1.5V alkaline batteries (type AAA)
Operating conditions
0°C … 40°C , Max. humidity 80% rH,
no condensation, Max. working altitude
Storage conditions -10°C ... 60°C, Max. humidity 80% rH
Dimensions (W x H x D) 154 x 32 x 28 mm
Subject to technical alterations. 11.17
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=acchk
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning
agents, scouring agents and solvents. Remove the battery(ies) before
storing for longer periods. Store the device in a clean and dry place.