Lauda PD 2 R Specifications

General IconGeneral
Temperature Range-20°C to 200°C
Temperature Stability±0.01°C
RefrigerantR134a
Power Supply230 V, 50/60 Hz
Bath Volume2 l
Heating Power2 kW
Cooling Capacity0.2 kW at 20°C

Summary

Operating Instructions

Puridest Distillation Apparatus Overview

Introduces the LAUDA Puridest Distillation Apparatus models.

LAUDA Puridest Distillation Apparatus

High-Purity Distillate Production

Produces highly-pure, bacteria and pyrogen-free distillate meeting pharmacopeia standards.

Apparatus Component Identification

Identifies key components like main switch, pilot lamps, and withdrawal tap.

Pre-installation Check and Contact

Advices checking package contents and contacting the supplier for damages or complaints.

Use of the Distillation Apparatus

Intended Use of Puridest Apparatus

Describes the apparatus's function for boiling water and producing distillate.

Improper Use and Restrictions

Lists restrictions on use, including not for medical devices or explosive environments.

LAUDA Apparatus Warranty

Details the warranty claim process and required information for defective units.

Before Unit Initiation

Safety Symbols and Warnings

Explains warning symbols for hot liquids, electrical voltage, and general warnings.

Set-up and Location of Apparatus

Transport and Placement Guidelines

Provides guidance on safe transport, lifting, and placement on stable, watertight surfaces.

Wall Mounting Instructions

Details how to use keyholes for wall mounting and the required fixing material.

Environmental Restrictions

States the unit is not suitable for potentially explosive surroundings.

Operation Voltage and Electrical Connection

Mains Connection Requirements

Specifies requirements for connection to the mains supply, including shock-proof sockets and earth conductor.

Water Connections Overview

Locates water connections on the right-hand side of the unit.

Water Connections Details

Distillate Withdrawal Procedure

Explains how to withdraw distillate using the front tap and connecting a hose.

Drain Boiler Procedure

Describes connecting a hose to drain the boiler for cleaning or maintenance.

Cooling Water Outlet Connection

Details connecting a hose to the cooling water outlet for drainage.

Tap Water Inlet Connection

Explains connecting the tap water inlet via a solenoid valve and pressure hose.

Unit Initiation Procedure

Before Initial Starting Steps

Instructions for filling the apparatus with water and re-assembling lids.

Initial Operation Steps

How to start the apparatus, including discarding initial distillate.

Unit Shutdown for Downtime

Procedure for switching off the unit for longer periods and emptying.

Functional Description of Puridest Apparatus

Automatic Operation Sequence

Explains the automatic sequence of operation, including pilot lamps and water level control.

Maintenance, Service, and Troubleshooting

Safety Precautions for Maintenance

Emphasizes cooling down the unit and disconnecting power before maintenance.

Descaling the Apparatus

Provides detailed steps for descaling using a descaling agent and rinsing.

Pilot Lamp Clean Procedure

Addresses issues like foam formation causing the "Clean" pilot lamp to light up.

Foam Formation Troubleshooting

Explains foam formation causes and the resulting unit shutdown.

Troubleshooting Common Issues

Back Water in Boiler Troubleshooting

Discusses causes for back water in the boiler and the "Clean" lamp indication.

Re-initiation After Low Water

Steps to reset the low water cut-off and re-initiate the unit.

Unit Care and Servicing Guidelines

Advice on handling, cleaning surfaces, and servicing by qualified personnel.

Disposal of Old Units

Environmental Disposal Responsibility

Explains LAUDA-GFL's responsibility for environmentally sound handling and recycling of units.

Technical Data for PD 2 R and PD 4 R

Dimensions and Capacity (PD 2 R / PD 4 R)

Provides exterior dimensions, storage tank size, and distillation capacity for models.

Distillate Quality Specifications

Details distillate quality parameters like conductivity and purity.

Operating Conditions (PD 2 R / PD 4 R)

Lists cooling water requirements, pressure, electrical connection, and ambient conditions.

Technical Data for PD 8 R and PD 12 R

Dimensions and Capacity (PD 8 R / PD 12 R)

Provides exterior dimensions, storage tank size, and distillation capacity for models.

Electrical and Operating Parameters (PD 8 R / PD 12 R)

Details electrical connections, mains supply, fuses, and operating conditions.

Circuit Diagram Overview

Circuit Diagram Component List

Lists and defines components used in the circuit diagrams.

Circuit Diagram for PD 2 R

Presents the electrical circuit diagram for the PD 2 R model.

Circuit Diagrams for PD 4 R and PD 8 R

Circuit Diagram for PD 4 R

Presents the electrical circuit diagram for the PD 4 R model.

Circuit Diagram for PD 8 R (230V/1~)

Shows the electrical circuit for the PD 8 R model with 230V/1~ connection.

Circuit Diagrams for PD 8 R / PD 12 R

Circuit Diagram for PD 8 R / PD 12 R (220V/3~)

Presents the electrical circuit for PD 8 R / PD 12 R models with 220V/3~ connection.

Circuit Diagram for PD 8 R / PD 12 R (400V/3~)

Shows the electrical circuit for PD 8 R / PD 12 R models with 400V/3~ connection.

Connection to the Mains Supply

Mains Connection Lead Colour Decoding

Explains the colour coding of wires for mains connection cables.

Model-Specific Mains Connections

Details compatibility for connecting PD 2/4 R and PD 8/12 R to different mains supplies.

Electrical Fuses and Power Consumption

Lists power consumption and required mains fuses for each model.

Examples for Mains Connection

Mains Connection Components

Lists components like sockets, plugs, and main switches for mains connection.

PD 2 R / PD 4 R Mains Connection (230V / 220V 3~)

Example connection for PD 2 R / PD 4 R to 220 V / 3 ~ mains supply.

PD 2 R / PD 4 R Mains Connection (230V / 400V 3~)

Example connection for PD 2 R / PD 4 R to 400 V / 3 ~ mains supply.

PD 8 R Mains Connection Examples

PD 8 R Mains Connection (230V/1~ to 220V/3~)

Example connection for PD 8 R (230V/1~) to 220 V / 3 ~ mains.

PD 8 R Mains Connection (230V/1~ to 400V/3~)

Example connection for PD 8 R (230V/1~) to 400 V / 3 ~ mains.

PD 8 R / PD 12 R Mains Connection Examples (220V/3~)

PD 8 R / PD 12 R Mains Connection (220V/3~ via Switch)

Example connection for PD 8 R / PD 12 R to 220 V / 3 ~ mains via switch.

PD 8 R / PD 12 R Mains Connection (220V/3~ via CEE Plug)

Example connection for PD 8 R / PD 12 R to 220 V / 3 ~ mains via CEE plug.

PD 8 R / PD 12 R Mains Connection Examples (400V/3~)

PD 8 R / PD 12 R Mains Connection (400V/3~ via Switch)

Example connection for PD 8 R / PD 12 R to 400 V / 3 ~ mains via switch.

PD 8 R / PD 12 R Mains Connection (400V/3~ via CEE Plug)

Example connection for PD 8 R / PD 12 R to 400 V / 3 ~ mains via CEE plug.

List of Spare Parts

Spare Parts Catalog by Part Number

Lists spare parts with part numbers and descriptions for various components.

Accessories and Options

Separate Water Supply Options

Describes options for separate water supply, with and without solenoid valve.

Water Filters and Cartridges

Details Dechlorite Filter and Phosphate cartridge for water pre-treatment.

Additional Accessories and Options

Pre-Filters and Wall Brackets

Describes pre-filters for tap water cleaning and wall brackets for filter mounting.

Hose Sets and Level Control Switch

Details hose sets for water connections and level control switches for external tanks.

EC Declaration of Conformity

Product Models and Technical Data

Declares conformity of Puridest models with EC Directives and lists technical data.

Applied EC Standards

Lists the standards applied for Low Voltage, EMC, and RoHS Directives.

Technical Documentation Representative

Identifies the authorized representative for technical documentation compilation.