EasyManua.ls Logo

Lauda Hydro H 16 A User Manual

Default Icon
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operating Instructions
Hydro Water Baths
H 4, H 8, H 16, H 22, H 24, H 41, H 8 A, H 16 A

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Lauda Hydro H 16 A and is the answer not in the manual?

Lauda Hydro H 16 A Specifications

General IconGeneral
ModelHydro H 16 A
Temperature Stability±0.01 °C
Bath Volume16 liters
Heating Capacity2 kW
RefrigerantR134a
Power Supply50/60 Hz

Summary

Use of the Water Bath

Intended Use

LAUDA Hydro Water Baths are used for temperature-controlled warming of different media.

Improper Use

Guidelines on prohibited uses and unsuitable media for the Water Bath.

Warranty Information

Before Installation and Initiation

Transport, Setup, and Location

Operating Voltage

Filling Water into the Water Bath

Functional Description and Initiation

Controller Key Functions

Explanation of membrane keys for navigating the controller interface.

Main Menu

Setting Process Parameters

Configure temperature, switch-on delay, and operation time.

Accessing Basic Settings

Navigation to advanced controller configuration options.

Switching to Menu Basic Settings

Temperature and Alarm Configuration

Setting temperature limits and alarm trigger points.

Display and Process Settings

Configuring display units, start options, and temperature calibration.

Navigation and Return

Switching back to the main menu from basic settings.

Display of Current Process Data

Function Control and Alarms

Malfunction Error Codes and Reset

Explanation of error codes and procedures for resetting malfunctions.

Water Circulation System

Maintenance and Support

General Safety and Maintenance Precautions

Important safety advice and general care instructions before maintenance.

Exchanging Internal Unit Fuses

Procedure for checking and replacing the internal fuses.

Low Water Cut-off

Under-temperature Alarm

Over-temperature Alarm

Temperature Sensor Interruption

Temperature Sensor Short Circuit

Cleaning and Maintenance Procedures

Descaling the Water Bath

Methods for removing lime deposits using descaling agents.

Unit Cleaning and Care

Procedures for cleaning stainless steel surfaces and general care.

Decontamination of Unit

Steps for decontaminating the unit after exposure to hazardous substances.

Disposal of Old Units

Technical Data

Circuit Diagram

Mains Connection Examples

Electrical Fuses

Details on electrical fuse types and ratings for different models.

Mains Connection Schematics

Spare Parts List

Accessories

Related product manuals