Problem Cause Solution
Low/no jet
pressure
Air lock Bleed air from the system (page 36)
Dirty filter Check and clean or replace filter
Closed jets Open all jets by turning CCW
Closed
valves
Open all gate valve shutoff valves on heater and
pumps
Low water Fill spa 1” above all jets (excluding neck jets)
Moved my spa
and now it
doesn’t work
Wiring error
at GFCI
Check Neutral wiring of GFCI (see diagrams on
pages 18 - 19 )
No power to
spa
Reset circuit breakers on GFCI panel and main
circuit breaker panel
No flow
Closed jets
Open jets
See also Circulation Pump on page 37
Nothing works
Breaker has
tripped
Check and reset breaker. If problem persists, check
for loose electrical connections. Check for Neutral
wiring error at GFCI.
pH changed
suddenly
Total
alkalinity
Check total alkalinity level and adjust if necessary
(see page 25)
Pump not
running
No power to
spa
Reset circuit breakers on GFCI panel and main
circuit breaker panel
Pump runs
continuous
Normal Normal
Sanitation
(chlorine) level
too high/low
Improper
level for use
Adjust level for use
Sanitation
(water) too
murky
Improper
filter cycle
time
Increase filter cycle time
Scaling
Hardness
level
Adjust hardness level
Speaker does
not pop up
Speaker
mechanism
broken
Replace speaker