LEAK TEST: VALVES, HOSE & REGULATOR
Turn the control knobs to OFF.
Connect the regulator to the LPG cylinder.
Completely open the LPG tank by turning the OPD hand
wheel counterclockwise.
• If you hear a rushing sound, turn gas o immediately. There is a major leak at the connection.
• Immediately close the LPG cylinder by turning the OPD hand wheel
clockwise and re-tighten connections. If leaks cannot be stopped
DO NOT TRY TO REPAIR.
Brush soapy solution
onto joint areas of valves and
regulator.
(Indicated by arrows in figure
0
2.)
• Leaks are indicated by
growing bubbles.
• Immediately close the LPG
cylinder by turning the OPD
hand wheel clockwise and
re-tighten connections.
WARNING
If leaks cannot be stopped, DO NOT try to repair.
Regulator must be replaced with a Blackstone approved
model by a professionally licensed, authorized dealer.
figure 02
DISCONNECTING THE LPG CYLINDER
Ensure that the control knobs are turned to OFF.
❶
Ensure that the LPG cylinder
is OFF by turning the OPD hand
wheel clockwise to a full stop.
❷
Turn the coupling nut count-
er-clockwise by hand to remove
the regulator. (DO NOT use tools
to disconnect.)
Place dust cap on LPG
cylinder valve outlet whenever
cylinder is not in use.
Only install the type of dust cap on
cylinder valve outlet that is provided
with the cylinder valve. Other types of
caps or plugs may result in leakage of
propane.
❶
❷
control knob to HUGH control knob to HIGH position.