6. OPERATIONS
6.1 Independent Operation
(
1)
When
the
+ terminal @ or
the
-terminal
@
is
to
be connected
always
to
the
GND terminal
GJ)
,
the
shortcircuit bar
as
an acces·
sory
should be connected
as
shown
in
Fig.
6·1
GND
+
SHORT-CIRCUIT
BAR
Fig.
6-1
(2) Connect
the
AC
power cord
to
the
power source
of
the
specified
valtage, and
turn
on
the
power switch. Then
the
pilot lamp will
come
on.
(3)
To
set
the
load voltage, slowly
turn
the voltage adjusting
knob@
clockwise with no load, while watching
the
amperemeter. The
knob
@
is
for coase adjustment, and
the
knob
@
is
for fine
adjustment.
(4)
Load
current
setting
is
used
to
limit
the
current applied
to
a
device
to
be tested at a specified power
or
to
protect
the
device
from
the
over current.
To
set
the
current,
connect
the
G)
and
8 terminals by a thick lead wire. Slowly
turn
the
current
adjust-
ment
knob
@,
and set
the
current
while watching
the
ampere-
meter indication.
At
this time, set
the
voltage adjustment knob
@full
counterclockwise and set
the
white mark of
the
FINE
adjustment knob
@at
the
middle.
The minimum
current
that
can be set
is
as
follows.
-11-