9
GB/IE
3. SET UP
3.1 Temperatures programming (set range : from +1’C to +5’C) :
- short pressing of (10) AUX button – entering/leaving set temperature programming
mode. Buttons (8)‘▼’ and (9)‘▲’ are used to adjust settings. Diode (11) blinking in-
dicates active function of set temperature programming; if button (8)‘▼’ or (9)‘▲’ is
not pressed, after 10 seconds since the last pressing of (8)‘▼’ or (9)‘▲’ the driver will
leave the described mode.
3.2 Deleting recorded exceedance (MIN / MAX):
- pressing buttons (8)‘▼’ and (9)‘▲’ for about 2-3sec results in deleting saved min/
max temperatures and saving current temperature in the driver’s memory
4. Defrostation
Defrostation is turned on automatically every 8 hours (C0 parameter). Maximum
length of defrostation is 30 minutes (C1 parameter).
Cooler compressor is turned off during defrostation.
Defrostation is nished also when the temperature of the evaporator is higher than +4
o
C.
If the evaporator temperature sensor is damaged, temperature-conditioned defrosta-
tion completion will not occur.
Defrostation occurs also when the cooler sensor is damaged and the compressor
works using emergency mode in the c6/c7 time cycle.
5. Alarms
A displayed alarm should be saved even if the reason of the alarm does not exist
anymore
Alarms are not saved after switch off (lack) of power.
E1 – cooler sensor malfunction – if the reason of the alarm still exists, it can not be
deleted,
E2 – evaporator sensor malfunction – if the reason of the alarm still exists, it can not
be deleted.
Hi – maximum set temperature of the product
Lo – minimum set temperature of the product exceeded
Pressing a random button deletes the sound signal as well as Hi and Lo indications.
E1,E2 deletion by means of turning off the on/off driver after prior elimination of a
malfunction