Initial setup:
ConnectthesuppliedmainspoweradaptortotheDCpowerinputonthecontrollerandthentoa
suitablemainsvoltagesupply(100-240VAC~50/60Hz).ConnecttheLEDxturesusingstandard3-pin
DMXdatacables.FollowthesetupprocedureforthecontrollerrstbeforepoweringontheLEDxtures.
Thecontrollercanbeusedtocontrol3or4colourLEDproductseachwithorwithoutadimmerchannel.
DMX channel assignment:
ThecontrollerhaspresetDMXstartaddressesforeachofthefourxtures.Pleasesetyourxturetothe
followingDMXaddresses.Pleasenote:IftwoormorexturesaresettothesameDMXaddresstheywill
receivethesameDMXcommands.Thecontrollercanbesetuptoaddressfourindividual3channelRGB
xturesaddressedsequentially(001,004,007and010)orifthexturesfeatureRGBWorRGBwitha
dimmerchanneltheycanbeaddressedwithsufcientspacingbetweenthexturestoaccountforthe
extrachannels(001,017,033and049).
Operating instructions
Fixture Number Group DMX Start Address - LED Par Cans/Panels DMX Start Address - Multi LED Bars (3CH RGB only)
1 001 001
2 017 004
3 033 007
4 049 010
Example of 4 RGBW par cans: