Dual Tech detector switch
CONTENTS
1. USE
This device automatically controls a light source by detecting movement
in its supervision zone.
Movement detector with 360° detection angle.
Detection methods: infrared (PIR) and ultrasound (US)
Mounting: ceiling.
2. TECHNICAL DATA
Voltage: 100 - 240 V~
Frequency: 50 / 60 Hz
No-load power consumption: 0.8 W
Output by normally closed contact connected to phase.
Cabling: 2 x 2.5 mm
2
Operating temperature: - C to + 45° C
Flush-mounting diameter: 65 mm without flush-mounting box,
68 mm with flush-mounting box
Weight: 162.2 g
Impact resistance: IK04
Penetration by solid/liquid bodies: IP20
Operating temperature: - C to + 45° C
Storage temperature: - 20°C to + 70° C
CONTENTS Page
1. Use...........................1
2. Technical data ..................1
3. Overall dimensions...............1
4. Connection .....................2
5. Installation .....................2
6. Removal .......................2
7. Settings .......................3
8. Performance....................3
9. Cleaning .......................3
10. Standards and approvals ..........4
3. OVERALL DIMENSIONS
Without auxiliary
With auxiliary
230 V~ 2000 W 8.5 A 2000 W 8.5 A 1000 VA 4.3 A 10x(2x36 W) 4.3 A 500 W 2.1 A 1000 VA 4.3 A
I max. 2A
110 V~ 1000 W 8.5 A 1000 W 8.5 A 500 VA 4.3 A 5x(2x36 W) 4.3 A 250 W 2.1 A 500 VA 4.3 A
1 2 3 4 5 6 7
50
58.97
51.5
R : 60.36
53.74
62.27
1 Incandescent lamp
2 Halogen lamp
3 Halogen lamp with separate ferromagnetic or electronic transformer
4 Fluorescent tubes
5 Compact fluorescent lamp with integrated ballast
6 Compact fluorescent lamp with separate ferromagnetic or electronic ballast
7 Contactors
IR reception LED
(for configuration tool
or remote control)
IR transmission LED
(for configuration tool)
LEARN keyPIR Sensor / Detector
US Detector / Sensor
Programming connector
Green detection
indicator light
Green programming
indicator light