Cat. No(s): 488 06
Dual Tech detector switch
Technical data sheet: F01013EN/00 Updated: Created: 29/09/2009
2/4
CONTENTS
5. INSTALLATION
6. REMOVAL
4. CONNECTION
Number of terminals: 4
Terminal type: automatic
Terminal capacity: 2 x 2.5 mm
2
Stripping length: 8 mm
Cabling with auxiliary control and multiple detector cabling with
auxiliary control: Manual ON / Auto OFF.
The light ca be activated manually by pressing the auxiliary control.
Press again to turn off. If no action is performed ont the control, the
detector will cut the related at the end of the time-out period or when
the brightness threshold is reached.
Cabling without auxiliary control: Auto ON / Auto OFF
The light automatically turns on and off.
Option: the detector can be controlled by infrared remote control
.
8.5 A
max.
100 m max.
8.5 A
max.
100 m
max.
8.5 A
max.
100 m
max.
1
2
3
1
2
50
Ø 68 Ø 65