LG00129-a-UK
SPE=0 M=0 Self-learning mode
To activate the programming pushbutton,
only use the screwdriver provided.
Possible function M configurator value
This operating mode can be used to associate one individual control to any key of the device. It is possible to create, delete or
change each control. A specific A/PL address on the system must always be assigned to the control (not to be used by any other
device installed on the BUS), with A=0 – 9 e PL=1 – 9.
0
Programming the Keys
1) Shortly press the key on the rear side, the LEDs will switch in succession;
2) Press, within 20 seconds, the key that needs to be programmed: the LED will
start flashing (0.5s on – 0.5s off), showing that the programming mode has been
enabled;
3) Set the control to be associated with the key using the keys and/or the
corresponding actuator; the LEDs will start to rotate;
4) You can now repeat operations 2 and 3 for all keys, including any keys already
associated, if they need changing;
5) Shortly press the key on the rear part or wait 20 seconds to exit the programming
phase;
Functions which the device can learn:
a. Automation
ON/OFF actuator; cycling mode operation. Short pressure: ON/OFF actuator;
prolonged pressure: dimmer regulation (only for point-point control)
Timed ON
Flashing
Shutters UP; shutters are rolled up until end of stroke, in bistable mode. Prolonged
pressure: UP function; short pressure: STOP
Shutters DOWN; shutters are rolled down until end of stroke, in bistable mode.
Prolonged pressure: DOWN function; short pressure: STOP
Lock/release actuator
Scenario retrieval from Scenario module 035 51
Scenario retrieval from Scenario programmer 035 65
b. Video door entry systems
– Door lock control (including during a conversation)
– Staircase light control
– Call to the floor (including general call)
c. Sound diffusion
Amplifier ON (always in the follow-me mode). Short pressure: amplifier ON;
prolonged pressure: volume regulation UP
Amplifier OFF. Short pressure: amplifier OFF; prolonged pressure: volume regula-
tion DOWN.
Cycling of sound sources.
Radio station or track change.
d. Auxiliary channels
ON/OFF light auxiliary; cycling mode operation
Shutters UP; shutters are rolled up until end of stroke, in bistable mode.
Prolonged pressure: UP function; short pressure: STOP
Shutters DOWN; shutters are rolled down until end of stroke, in bistable mode
Prolonged pressure: DOWN function; short pressure: STOP
Reset
The configuration can be made in two different modes:
- Physical configuration: connecting the physical configurators to their own
housings
- Virtual configuration: the control may be configured remotely
Configuration
672 43