Kathryn CochranAug 15, 2025
What to do if Leica PIPER 100 shows Empty Battery?
- WWanda FlynnAug 15, 2025
If your Leica Measuring Instruments indicates an Empty Battery, remove and replace or recharge the battery.
What to do if Leica PIPER 100 shows Empty Battery?
If your Leica Measuring Instruments indicates an Empty Battery, remove and replace or recharge the battery.
What to do if Leica Measuring Instruments show Temperature Limit?
If your Leica Measuring Instruments display a Temperature Limit warning, this is often due to direct sunlight. The suggested solution is to shade the unit to reduce the temperature.
What to do if Leica PIPER 100 Measuring Instruments shows Target Question?
If your Leica Measuring Instruments display a Target Question error, consider the following possibilities: * The target may be missing or not positioned properly. Ensure the reflective tapes are facing the Piper. * The laser beam might be blocked. Check for obstructions and try again. * The target might be too far for Alignmaster to find it. If possible, move the target closer. * The Piper could be positioned outside Alignmaster's seek area. Reposition the Piper and try again.
What to do if Leica PIPER 100 beam is not hitting the center of the target?
If the beam of your Leica Measuring Instruments isn't hitting the target's center, it could be due to several reasons: * The Piper or target might not be set up correctly or has been moved. Check the setup and try again. * The pipe might not be correctly adjusted to grade. Verify the grade adjustment and try again. * The pipe or water inside it could be reflecting the beam. If possible, drain the pipe and retry. * Conditions inside the pipe might be refracting the beam. Consult the section on refraction for a remedy. * The Piper might be out of adjustment. Perform an accuracy check.
Why is my Leica PIPER 100 Measuring Instruments Remote Control not functioning?
If the remote control for your Leica Measuring Instruments isn't working, consider these potential causes: * Line movement may be locked. * The remote might be too far from the Piper. Move closer and try again. * The remote's battery might be low. Replace the battery and try again.
What to do if Leica PIPER 100 Measuring Instruments shows Target, Question Mark, and Sun Icon?
If your Leica Measuring Instruments displays a Target, Question Mark, and Sun Icon, try shading the unit to reduce the sun's effects.
What to do if Leica PIPER 100 Line and Grade will not change?
If the line and grade settings on your Leica Measuring Instruments won't change, it could be due to: * The line and grade may have been locked. Press the STAR button, then a line or grade button to unlock it. * The line or grade may have reached its furthest limit. Line limits are indicated by the icon at the top of the display.
What to do if Leica Measuring Instruments shows Servo Limit?
If your Leica Measuring Instruments displays a Servo Limit error, reposition the Piper in the direction of the arrow until the unit can once again level itself.
How to fix Roll Icon on Leica PIPER 100?
To resolve the Roll Icon issue on Leica Measuring Instruments, reposition the Piper in the direction of the arrow until the vial is centered.
Laser Class | Class 2 |
---|---|
Self-leveling range | ± 5° |
Operating temperature | -10°C to +50°C |
Storage temperature | -20°C to +70°C |
Laser beam divergence | 1.5 mrad |
Working range | Up to 150 meters |
Battery Type | Alkaline |
Battery Life | 70 h |
Laser Type | Diode laser, 635 nm, visible red |
General safety directions, warning messages, user responsibilities, and product use limits.
Details hazards of use, lifetime warranty terms, and laser classification and safety standards.
Covers powering on, startup screens, LCD display, and control buttons.
Guides on setting grade, line, elevation, and using lock functions.
Explains the Alignmaster function, its setup, and troubleshooting.
Guides on how to check and adjust the instrument's accuracy.
Step-by-step instructions for accessing and performing accuracy adjustments.
Lists common display items, symptoms, and their possible causes and solutions.