Leica PIPER 100 - User Manual

Leica PIPER 100
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Leica Piper 100/200
User Manual
Version 5.0
English

Questions and Answers

  • K
    Kathryn CochranAug 15, 2025
    What to do if Leica PIPER 100 shows Empty Battery?
    • W
      Wanda FlynnAug 15, 2025
      If your Leica Measuring Instruments indicates an Empty Battery, remove and replace or recharge the battery.
  • R
    Ruben RileyAug 18, 2025
    What to do if Leica Measuring Instruments show Temperature Limit?
    • A
      Ann SullivanAug 18, 2025
      If your Leica Measuring Instruments display a Temperature Limit warning, this is often due to direct sunlight. The suggested solution is to shade the unit to reduce the temperature.
  • D
    danielleporterAug 21, 2025
    What to do if Leica PIPER 100 Measuring Instruments shows Target Question?
    • G
      Garrett NelsonAug 21, 2025
      If your Leica Measuring Instruments display a Target Question error, consider the following possibilities: * The target may be missing or not positioned properly. Ensure the reflective tapes are facing the Piper. * The laser beam might be blocked. Check for obstructions and try again. * The target might be too far for Alignmaster to find it. If possible, move the target closer. * The Piper could be positioned outside Alignmaster's seek area. Reposition the Piper and try again.
  • C
    chris85Aug 25, 2025
    What to do if Leica PIPER 100 beam is not hitting the center of the target?
    • R
      Robert AdamsAug 26, 2025
      If the beam of your Leica Measuring Instruments isn't hitting the target's center, it could be due to several reasons: * The Piper or target might not be set up correctly or has been moved. Check the setup and try again. * The pipe might not be correctly adjusted to grade. Verify the grade adjustment and try again. * The pipe or water inside it could be reflecting the beam. If possible, drain the pipe and retry. * Conditions inside the pipe might be refracting the beam. Consult the section on refraction for a remedy. * The Piper might be out of adjustment. Perform an accuracy check.
  • A
    Alexis HarrisAug 28, 2025
    Why is my Leica PIPER 100 Measuring Instruments Remote Control not functioning?
    • L
      Lisa KellyAug 28, 2025
      If the remote control for your Leica Measuring Instruments isn't working, consider these potential causes: * Line movement may be locked. * The remote might be too far from the Piper. Move closer and try again. * The remote's battery might be low. Replace the battery and try again.
  • L
    Leah AcevedoAug 31, 2025
    What to do if Leica PIPER 100 Measuring Instruments shows Target, Question Mark, and Sun Icon?
    • S
      sharonrobertsAug 31, 2025
      If your Leica Measuring Instruments displays a Target, Question Mark, and Sun Icon, try shading the unit to reduce the sun's effects.
  • H
    heather62Sep 4, 2025
    What to do if Leica PIPER 100 Line and Grade will not change?
    • P
      perezronaldSep 4, 2025
      If the line and grade settings on your Leica Measuring Instruments won't change, it could be due to: * The line and grade may have been locked. Press the STAR button, then a line or grade button to unlock it. * The line or grade may have reached its furthest limit. Line limits are indicated by the icon at the top of the display.
  • C
    carolyn58Sep 7, 2025
    What to do if Leica Measuring Instruments shows Servo Limit?
    • E
      ericksonmarkSep 7, 2025
      If your Leica Measuring Instruments displays a Servo Limit error, reposition the Piper in the direction of the arrow until the unit can once again level itself.
  • T
    tommyschultzSep 12, 2025
    How to fix Roll Icon on Leica PIPER 100?
    • S
      Sara RichardsSep 12, 2025
      To resolve the Roll Icon issue on Leica Measuring Instruments, reposition the Piper in the direction of the arrow until the vial is centered.

Summary

Safety Directions

General Safety and Responsibilities

General safety directions, warning messages, user responsibilities, and product use limits.

Hazards, Warranty, and Laser Safety

Details hazards of use, lifetime warranty terms, and laser classification and safety standards.

Basic Operation

Device Overview and Controls

Covers powering on, startup screens, LCD display, and control buttons.

Setting Core Functions

Guides on setting grade, line, elevation, and using lock functions.

Alignmaster Functionality

Explains the Alignmaster function, its setup, and troubleshooting.

Standard Setup Procedures

Accuracy Adjustment

Checking and Adjusting Accuracy

Guides on how to check and adjust the instrument's accuracy.

Adjustment Procedures

Step-by-step instructions for accessing and performing accuracy adjustments.

Checking Line and Grade

Troubleshooting

Common Issues and Solutions

Lists common display items, symptoms, and their possible causes and solutions.

Leica PIPER 100 Specifications

General IconGeneral
Laser ClassClass 2
Self-leveling range± 5°
Operating temperature-10°C to +50°C
Storage temperature-20°C to +70°C
Laser beam divergence1.5 mrad
Working rangeUp to 150 meters
Battery TypeAlkaline
Battery Life70 h
Laser TypeDiode laser, 635 nm, visible red