Enclosure Climate Control Unit Assembly Instructions
(FCC品)
FCC225
FCC320
FCC680
FCC825
FCC1100
FCC1500

Questions and Answers

  • J
    Jonathan WyattAug 12, 2025
    Why is my Leizig FCC225 system high pressure alarm going off?
    • L
      lawsonphillipAug 12, 2025
      The high pressure alarm in your Leizig Temperature Controller system may be triggered by several issues. It could be due to dirt on the condenser, which requires cleaning. Another cause might be incondensable air in the system, suggesting you need to vacuumize and refill the refrigerant. A blocked condenser fan filter mesh, which requires cleaning, or a condenser fan that won't start, potentially needing a capacitor replacement, could also be the cause.
  • K
    Kathleen GlassAug 20, 2025
    What to do if my Leizig FCC225 compressor is not working?
    • W
      William GarzaAug 20, 2025
      If the compressor of your Leizig Temperature Controller isn't working, several factors could be responsible. It could be due to abnormal voltage, in which case you should adjust the capacity of the mains power supply, voltage, and output. Alternatively, a faulty contactor or thermostat malfunction could be the cause, suggesting you replace the contactor or replace the thermostat if disconnected, or adjust its accuracy if connected. Other potential causes include an overheat protector burnout (replace if disconnected), capacitor aging (replace the capacitor), or a program error on the control panel (replace it after cause clarification).
  • L
    Lisa ConwayAug 27, 2025
    Why does the air switch trip after Leizig FCC225 Temperature Controller AC startup?
    • C
      Cassidy MackAug 27, 2025
      The air switch tripping after your Leizig Temperature Controller AC starts up could be due to several reasons. It might be a breaker malfunction, suggesting the breaker's capacity should be 1.5 times the AC working current. Other potential causes include a compressor malfunction or system leakage, in both cases you should contact the manufacturer. Also, a blocked condenser fan filter mesh could be the cause, in this case clean the filter mesh.
  • T
    Tammy LewisSep 2, 2025
    What to do if Leizig Temperature Controller compressor and fans are working but not cooling?
    • N
      nathan72Sep 2, 2025
      If your Leizig Temperature Controller's compressor and fans are running but not cooling, it could be due to refrigerant leakage or a dirt blockage. For refrigerant leakage, test and mend the leakage, pressurize and vacuumize the system, and contact the manufacturer for commissioning after refrigerant refilling. If it's a dirt blockage, replace the filter dryer, pressurize and vacuumize the system, and contact the manufacturer for commissioning after refrigerant refilling.

Leizig FCC225 Specifications

General IconGeneral
Control AlgorithmPID, ON/OFF
Input TypeThermocouple
Output TypeRelay, SSR
Display TypeLED
Operating Temperature0°C to 50°C