Safety Tips
(1) Precautions - Do not use if you are using a pacemaker, insulin pump or other internally implanted
electronics whose function may be influenced by dynamic magnetic fields and induced electrical
current. Also, do not use this product on the brain. We do not recommend use of this machine on the
brain for any reason.
(2) Make Sure the Treatment Rope is Intact - Inspect the rope before use to make sure the insulation
(ie: white part of the rope) is not torn, damaged or severed such that the wire inside is exposed. If the
insulation is broken, STOP! Do not use that rope. Use a different accessory or visit our website to order
a replacement.
(3) Avoid Using Outlets Controlled by a Light Dimmer - The magnetic field generated by the PEMF
4000 causes small electronics like those inside of light dimmers to malfunction. It will create a surge of
electricity that can damage either your PEMF unit or the light dimmer attached to the outlet. Make sure
the outlet you use is not controlled by a light dimmer before you power the unit on!
(4) Give the Fans Room to Breathe - If the fans are blocked or stopped this may cause internal
damage to your PEMF 4000. Always make sure nothing can stop or slow the airflow from the fans
while the unit is powered on. Also ensure that no dust and debris can be sucked up by the fan.
(5) Power Down Before Changing Accessories - Stop the session and power the unit down before
swapping accessories. Make sure the cables snap securely into the connectors before powering on
again.
(6) Dealing with “Cleansing Crisis” - The PEMF 4000 stimulates cell metabolism functions. These
functions include releasing toxins to be removed by your immune system. Cleansing crisis happens
when the immune system becomes overloaded by detoxifying the body too fast. To help the body flush
the toxins, drink a large glass of water after each treatment.
(7) Always Use the Handles on the Case to Move the Unit - The strain from pulling on the Treatment
Rope connectors or the power cord will damage your device. Tugging may also damage the wires.
Always use the suitcase handles or roll it on its wheels to move, adjust, swivel and transport your unit.
(8) Do Not Drop or Toss the Unit - While the case is durable, remember it mainly lends external
protection to the sensitive electronics inside. Dropping and tossing the unit may cause internal damage.
Always put the unit down with care. And make sure the unit is fastened securely and padded for
minimal movement during travel.
(9) Storing Treatment Accessories - Avoid storing the rope or other accessories inside of the suitcase
of the machine where it can press down on the front panel and damage it. Store accessories separately.
(10) Do not expose to water - Do not allow the unit to get wet. If it does, dry it as best you can. If the
water gets inside of the machine, wait overnight for it to dry out. Do NOT power it on during this time.
If you receive your unit and find the front panel is wet with dew from changing temperatures during
shipping, make sure to dry it well especially around the accessory connectors and wait overnight for it
to dry internally before powering up.