Lennox Allied Air A96UH2E - Field Wiring Applications With Conventional Thermostat; Table 13 A.

Lennox Allied Air A96UH2E
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
507581-04 Page 45 of 60Issue 2128
Thermostat
DIP Switch Settings and On-Board Links
Wiring Connections
DIP Switch 1
Thermostat
Heating
Stages
On Board Links Must Be Cut To Select
System Options
1 Heat / 1 Cool
NOTE - Use DIP
switch 2 to set
second-stage
heat ON delay.
OFF-7 minutes.
ON-12 minutes.
ON
DO NOT CUT ANY
ON-BOARD LINKS
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
1 Heat / 2 Cool
NOTE - Use DIP
switch 2 to set
second-stage
heat ON delay.
OFF-7 minutes.
ON-12 minutes.
ON
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
1 Heat / 2 Cool
with t'stat with
humidity control
NOTE - Use DIP
switch 2 to set
second-stage
heat ON delay.
OFF-7 minutes.
ON-12 minutes.
ON
CUT ON-BOARD LINK
W915
2 STAGE
COMPR
CUT ON-BOARD LINK
W914
DEHUM
DEHUM
S1
T'STAT
FURNACE
TERM. STRIP
OUTDOOR
UNIT
*Not required on all units
*
G
G
O
W1
W1
W2
C
C
C
Y2
Y2
Y1
Y1
Y1
R
R
R
Y2
DS
DS
*
G
G
O
W1
W
W2
C
C
C
Y2
Y2
Y1
Y1
Y1
R
R
R
Y2
DS
*
G
G
O
W1
W1
W2
C
C
C
Y1
Y1
Y1
R
R
R
Y2
DS
W2
Field Wiring Applications With Conventional Thermostat
Table 13A.