0650329-56 / 506265-03 Issue 1924 Page 7 of 13
Control Board Taps
Model Mode
Thermostat Cool Heat
HUM EM W1 O
Y2/
Y1
G A B C D A B C D
CFM CFM
EFV08BCP 
Cont. Blower X 500 400 350 350
Cooling ** X X 1000 800 700 600
Heating X 1000 800 700 600
Aux. Heat X X *** *** *** *** 1000 800 700 600
Emer. Heat X X *** *** *** *** 1000 800 700 600
EFV12BCP 
Cont. Blower X 600 500 400 350
Cooling ** X X 1200 1000 800 600
Heating X 1200 1000 800 600
Aux. Heat X X *** *** *** *** 1200 1100* 1100* 1100*
Emer. Heat X X *** *** *** *** 1200 1100* 1100* 1100*
EFV16CCP 
Cont. Blower X 800 700 600 500
Cooling ** X X 1600 1400 1200 1000
Heating X 1600 1400 1200 1000
Aux. Heat X X *** *** *** *** 1600 1400 1200* 1100*
Emer. Heat X X *** *** *** *** 1600 1400 1200* 1100*
EFV20DCP 
Cont. Blower X 900 800 700 600
Cooling ** X X 1800 1600 1400 1200
Heating X 1800 1600 1400 1200
Aux. Heat X X *** *** *** *** 1800 1600 1400 1200*
Emer. Heat X X *** *** *** *** 1800 1600 1400 1200*
* This CFM is not approved for use with highest kW heater size.
** Humidistat will reduce cooling airow by 10% in high humidity.
*** Air ow is greater of COOL and HEAT when both electric heat and heat pump are operating.
ADJUST tap (+) will increase airow by 10%, while tap (-) will decrease airow by 12%.
ADJUST tap TEST will cause the motor to run at 70% of full airow. Use this for troubleshooting only.
At the start of a call for cooling there is a short run at 82% of airow for 7.5 minutes.
At the end of a call for cooling there is a blower delay of 1 minute.
Table 2. Variable Speed Motor Application