WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
NOTICE
A thermostat is not included and must be ordered
separately.
A Lennox communicating thermostat must be used in
communicating applications.
In non-communicating applications, the Lennox
ComfortSense® thermostat may be used, as well as
other non-communicating thermostats.
In all cases, setup is critical to ensure proper system
operation.
Field wiring for both communicating and non-
communicating applications is illustrated in diagrams,
which begin on page 29.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
CBA25UHV
IMPORTANT: Special procedures are required for clean-
ing the all-aluminum coil in this unit. See page 30 in this
instruction for information.
Table of Contents
CBA25UHV Unit Dimensions – Upow – inches (mm)...2
Specications and Electrical Data ..................................3
Model Number Identication ...........................................4
Adjusting the BDC3 Blower Control ...............................4
Adjusting the Blower Speed ..........................................4
Blower Data ....................................................................6
Application ....................................................................10
Unit Components ..........................................................10
ECBA25 Electric Heat Data ..........................................12
Heat Section Installation ...............................................17
Conguration Modication ........................................... 19
Brazing Connections ...................................................22
Installing the Condensate Drain ..................................24
Electrical Connections ................................................. 26
Inspecting and Replacing Filters .................................27
Wiring Diagrams ...........................................................28
Professional Maintenance ...........................................30
Check-out Procedures .................................................30
Sequence of Operation ................................................31
Service Literature
UNIT INFORMATION
Corp. 1917-L9
September 20, 2019
CBA25UHV (HFC-410A) SERIES UNITS
General Information
This indoor unit with all-aluminum coil is designed for
installation with optional eld-installed electric heat and a
matched outdoor unit that is charged with HFC-410A re-
frigerant. These units, designed for indoor installation in
multiple positions, are completely assembled for upow
and horizontal right-hand discharge before being shipped
from the factory.
All CBA25UHV air handlers are equipped with a facto-
ry-installed, internally mounted check / expansion valve,
which is suitable for use in HFC-410A applications.
This air handler is compatible with the ComfortSense®
non-communicating thermostat and non-communicating
outdoor units. In addition, this unit has the enhanced ca-
pability of communicating with communicating thermo-
stats and communicating outdoor units using the Lennox
RSBus protocols.
NOTE - For downow or horizontal left-hand air discharge,
certain eld modications are required.
Question and Answer IconNeed help?

Do you have a question about the Lennox CBA25UHV-060 and is the answer not in the manual?

Lennox CBA25UHV-060 Specifications

General IconGeneral
BrandLennox
ModelCBA25UHV-060
CategoryAir Conditioner
LanguageEnglish

Summary

Blower Control and Speed Adjustment

Adjusting Blower Speed

Instructions on how to adjust blower speed using jumpers on the BDC3 control for optimal performance.

Jumper Settings for Blower Control

Adjust Jumper Settings

Details on how to adjust motor speed using the ADJUST jumper for desired CFM.

Cool Jumper Settings

Explanation of the COOL jumper's function in determining CFM for cooling/heat pump modes.

Heat Jumper Settings

Description of the HEAT jumper's role in determining CFM for electric heat operation.

Heat Section Installation Procedures

Prepare Heat Element Installation

Step-by-step instructions for preparing the unit for heat section installation.

Install Heat Element Assembly

Procedure for securing the electric heater assembly into the air handler unit.

Brazing Connections Procedure

Refrigerant Line Set Requirements

Table specifying line set sizes for different models and refrigerant connections.

Condensate Drain Installation

Drainage, Duct System, and Connections

Connecting Refrigerant Lines

Procedures for routing, connecting, and brazing refrigerant lines to the coil.

Refrigerant Lines and Unit Sealing

Refrigerant Lines Installation Guide

Procedures for routing, connecting, and brazing refrigerant lines to the coil.

Electrical Connections and Filter Service

Making Electrical Connections

Step-by-step guide for making field electrical connections to the unit.

Wiring Diagrams

Maintenance and Operational Checks

Check-out Procedures

Procedures to verify proper installation and component function before system operation.

Pre-Start-Up Checks

A checklist of critical items to verify before initial start-up of the unit.

Sequence of Operation