EasyManua.ls Logo

Lennox CHA16-024 - SPECIFICATIONS CHP16

Lennox CHA16-024
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 4
SPECIFICATIONS CHP16
Model No. CHP16Ć024 CHP16Ć030 CHP16-036 CHP16-048 CHP16-060
Nominal Tonnage 2 2-1/2 3 4 5
Cooling capacity - Btuh (kW) 23,800 (7.0) 29,000 (8.5) 34,600 (10.1) 46,500 (13.6) 55,000 (16.1)
LARI
Cooling
Total unit watts 2615 3185 3870 4915 6225
C
ooling
Ratings
SEER (Btuh/Watts) 10.0
Ratings
EER (Btuh/Watts) 9.1 8.6 9.5 8.8
LARI High
Total capacity - Btuh (kW) 23,800 (7.0) 29,400 (8.6) 35,800 (10.5) 49,500 (14.5) 57,500 (16.8)
LARI High
Tem
p
erature
Total unit watts 2235 2780 3430 4605 5765
Temperature
Heating
Ratings
C.O.P. (Coefficient of Performance) 3.12 3.10 3.06 3.14 2.94
R
a
ti
ngs
HSPF - Region IV (Region V) 6.6 (5.9)
LARI Low
Total capacity - Btuh (kW) 12,800 (3.7) 17,000 (5.0) 22,800 (6.7) 28,000 (8.2) 33,600 (9.8)
LARI
L
ow
Temperature
Hti Rti
Total unit watts 1855 2330 3182 3800 5045
p
Heating Ratings
C.O.P. (Coefficient of Performance) 2.02 2.14 2.10 2.16 1.98
*Sound Rating Number (db) 80 82
Refrigerant Charge (HCFC-22)
5 lbs. 10 oz.
(2.55 kg)
6 lbs. 0 oz.
(2.72 kg)
7 lbs. 0 oz..
(3.18 kg)
10 lbs. 12 oz.
(4.88 kg)
10 lbs. 5 oz.
(4.68 kg)
Indoor Coil
Blower
Blower wheel nominal diameter x width in. (mm)
9 x 8
(229 x 203)
10 x 7 (254 x 178)
10 x 8
(254 x 203)
11-1/2 x 8
(292 x 203)
Blower
Motor horsepower (W) 1/3 (249) 1/2 (373) 3/4 (560)
Id
Net face area - sq. ft. (m
2
) 3.2 (0.30) 4.1 (0.38) 5.8 (0.54)
Indoor
Coil
Tube diameter - in. (mm) & No. of rows 3/8 (9.5) - 3
Coil
Fins per inch (m) 15 (591)
Net face area
Outer coil 8.6 (0.80) 14.3 (1.33)
Outdoor
Net
face
area
sq. ft. (m
2
)
Inner coil 5.3 (0.49) 8.3 (0.77) 9.9 (0.92) 13.8 (1.28)
Outdoor
Coil
Tube diameter - in. (mm) & No. of rows 3/8 (9.5) - 1.6 3/8 (9.5) - 2
Fins per inch (m) 20 (787)
Diameter - in. (mm) & No. of blades 20 (508) - 4 24 (610) - 4
Outdoor
Coil
Air volume - cfm (L/s) 2350 (1110) 2200 (1040) 3600 (1700)
C
oil
Fan
Motor horsepower (W) 1/6 (124) 1/4 (187)
Fan
Motor watts 220 340
Condensate drain size mpt - in. (mm) 3/4 (19)
No. & size of cleanable polyurethane filters - in. (mm) (1) 16 x 25 x 1 (406 x 635 x 25) ( 1) 20 x 25 x 1 (508 x 635 x 25)
Net weight of basic unit - lbs. (kg) 332 (151) 340 (154) 354 (161) 535 (243)
Shipping weight of basic unit - lbs. (kg) 1 package 417 (187) 426 (193) 436 (198) 610 (277)
Electrical characteristics - (60hz) 208/230v - 1 phase 208/230v - 1 ph, 208/230v or 460v - 3 ph
ECH16R-5
Output - Btuh (kW) 19,000 (5.6) - - - -
ECH16R-5
ECH16-5
lA.F.U.E. 99.0% - - - -
ECH16R-7
Output - Btuh (kW) 26,000 (7.6) 27,000 (7.9) 26,000 (7.6) 27,000 (7.9)
ECH16R-7
ECH16-7
lA.F.U.E. 99.0%
Optional
ECH16R-10
Output - Btuh (kW) 36,000 (10.5) 37,000 (10.8) 36,000 (10.5) 37,000 (10.8)
Optional
Electric
ECH16R-10
ECH16-10
lA.F.U.E. 99.0%
Electric
Heat
Ratings
ECH16 15
Output - Btuh (kW) 53,000 (15.5) 54,000 (15.8) 53,000 (15.5) 54,000 (15.8)
R
a
ti
ngs
ECH16-15
lA.F.U.E. 99.0%
ECH16 20
Output - Btuh (kW) - - - - 70,000 (20.5) 71,000 (20.8)
ECH16-20
lA.F.U.E. - - - - 99.0%
ECH16 25
Output - Btuh (kW) - - - - 88,000 (25.7)
ECH16-25
lA.F.U.E. - - - - 99.0%
*Sound Rating Number in accordance with test conditions included in ARI Standard 270.
LRated in accordance with ARI Standard 210/240;
Cooling Ratings - 95_F (35_F) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering indoor coil air
High Temperature Heating Ratings - 47 _F (8_C) db/43_F (6_C) wb outdoor air temperature and 70_F (21_C) entering indoor coil air
Low Temperature Heating Ratings - 17_F (-8_C) db/15_F (-9_C) wb outdoor air temperature and 70_F (21_C) entering indoor coil air.

Related product manuals