Lighting Information and Operation
WARNING
If you do not follow these instructions exactly, a fire
or explosion may result causing property damage,
personal injury or loss of life.
BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
Use only your hand to turn the gas control knob(s). Never
use tools. If the knob will not turn by hand, do not try to repair
it, call a qualified service technician. Force or attempted re-
pair may result in a fire or explosion.
PLACING UNIT INTO OPERATION
(Millivolt Valves with Piezo Ignitor)
Fireplaces which include a millivolt valve are equipped
with a pilot which must be lit by a Piezo ignitor (red ignitor
button). When lighting the pilot, follow these instructions
exactly.
GAS VALVE OPERATION - Millivolt Valve (Figure 2)
1- STOP! Read the safety information at the beginning
of this section.
2- In applications using an optional wall-mounted
switch or optional thermostat - Turn OFF ap-
pliance-mounted switch and leave OFF. Turn OFF
wall-mounted switch or set thermostat to lowest set-
ting.
In applications using only an appliance-mounted
switch - Turn OFF appliance-mounted switch.
3 - T urn off all electrical power to appliance.
Insert the tip of a finger of each hand (with the back of the
hands toward the panel) into the cutout in the bottom of
the panel at the positions shown, and rotate the panel
down.
The cont rol access pan el b ecomes hot during
unit operation, and must be opened with care:
TO OPEN THE CONTROL ACCESS PANEL
FIGURE 1
4 - Open the control access panel. See figure1. Push in
gas control knob slightly and turn clockwise
to OFF.
NOTE - Knob cannot be turned from PILOT to OFF un-
less knob is pushed in slightly . Do not force.
5 - W ait five (5) minutes to clear out any gas. If you then
smell gas, STOP! Immediately call your gas supplier
from a neighbor’s phone. Follow the gas supplier’s in-
structions. If you do not smell gas go to next step.
6 - Pres s partially and turn gas valv e knob counter-
clockwise
to PILO T.
7 - Push control knob in until it stops and hold knob in this
position. Immediately light the pilot by pushing the red
Piezo ignitor button. Continue to press control knob for
25 seconds after the pilot is lit. Release knob. It should
pop back up. Pilot should remain lit. If pilot goes out, re-
peat steps 5 through 10.
MILLIVOLT GAS VALVE
GAS VALVE SHOWN IN PILOT POSITION
CONTROL
KNOB
HI/LO FLAME
ADJUSTMENT KNOB
FIGURE 2
8 - Press partially and turn gas valve knob counterclock-
wise
to ON.
9 - Restore electrical power to appliance (if applicable)
10- In applications using an optional wall-mounted
switch or optional thermostat - Turn ON wall-
mounted switch or set thermostat to desired setting.
In applications using only an appliance-mounted
switch - Turn ON appliance-mounted switch.
11- Close the control access panel.
NOTE - If gas valve is turned to OFF from ON or PILOT
while appliance is in operation, gas valve will latch in OFF
position for 25 seconds.
TURNING OFF GAS TO UNIT
1- TurnOFF appliance-mounted switch, and in addition, if
wall-mounted switch or thermostat is used, turn OFF
wall-mounted switch or set thermostat to lowest setting.
2 - T urn off all electrical power to appliance.
3 - Open the control access panel. See figure1.
4 - Push in gas control knob slightly and turn clock-
wise
to OFF. Do not force.
5 - Close the control access panel.