BLOWER DATA
EL296UH090XV36C BLOWER PERFORMANCE (less lter)
SINGLE SIDE RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm Second Stage Heating Speed - cfm
+24% 1170 1245
+18% 1125 1190
+12% 1075 1145
+6% 1005 1075
Factory Default 935 1030
–6% 880 950
–12% 810 890
–18% 775 820
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm Second Stage Cooling Speed - cfm
Low Medium-Low Medium-High
2
High Low Medium-Low Medium-High
2
High
+ 610 705 795 920 840 1015 1165 1300
Factory Default 560 640 715 810 770 910 1050 1190
– 525 605 665 725 695 795 945 1110
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specic DIP Switch Settings.
2
Factory default setting.
NOTES - The eect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 250 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 250 cfm.
EL296UH090XV36C BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage Second Stage
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low 13 30 46 62 75 93 110 129 143 42 60 83 101 122 144 163 181 206 219 241
Med-low 25 45 62 80 96 115 134 151 173 78 104 122 144 170 195 215 239 265 283 308
Med-High 36 55 79 95 117 139 156 178 199 133 154 175 213 236 269 282 309 336 357 381
High 62 83 105 128 148 163 193 210 234 210 229 259 291 317 344 366 391 415 441 466
Factory Default
Cooling
Speed
Low 9 28 38 55 71 83 100 116 135 28 48 65 86 104 124 142 164 182 199 219
Med-low 20 38 52 69 83 102 120 135 152 59 81 100 125 142 162 182 204 229 248 269
Med-High 26 46 63 83 101 117 141 157 178 95 118 142 165 192 213 244 264 288 314 329
High 39 59 81 98 121 143 161 180 202 149 171 199 229 257 285 306 330 359 389 403
– Setting
Cooling
Speed
Low 8 23 35 52 66 80 95 108 121 21 41 56 71 91 110 126 144 164 179 197
Med-low 12 29 44 59 75 92 111 126 140 35 56 73 95 115 137 155 176 198 216 235
Med-High 20 37 56 71 86 104 122 143 155 70 89 114 135 157 175 199 225 242 266 282
High 27 47 67 82 102 124 142 160 181 104 125 150 178 207 232 251 273 297 321 350