Page 21
BLOWER DATA
EL296UH110XV48C BLOWER PERFORMANCE (less lter)
SINGLE SIDE RETURN AIR WITH OPTIONAL RETURN AIR BASE
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed
DIP Switch
Settings
First Stage Heating Speed - cfm Second Stage Heating Speed - cfm
+24% 1465 1560
+18% 1370 1490
+12% 1310 1400
+6% 1235 1340
Factory Default 1185 1270
–6% 1120 1210
–12% 1060 1120
–18% 1015 1065
COOLING
1
Cooling Speed
DIP Switch
Settings
First Stage Cooling Speed - cfm Second Stage Cooling Speed - cfm
Low Medium-Low Medium-High
2
High Low Medium-Low Medium-High
2
High
+ 800 935 1055 1190 1085 1285 1500 1680
Factory Default 745 860 980 1100 1015 1185 1355 1550
– 670 790 890 1025 920 1075 1240 1385
1
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specic DIP Switch Settings.
2
Factory default setting.
NOTES - The eect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 380 cfm.
Lennox iHarmony
®
Zoning System Applications - Minimum blower speed is 380 cfm.
EL296UH110XV48C BLOWER MOTOR WATTS (COOLING)
1
Cooling Speed
DIP Switch
Settings
Motor Watts @ Various External Static Pressures - in. wg.
First Stage Second Stage
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
+ Setting
Cooling
Speed
Low 35 58 79 99 120 148 166 192 209 73 108 132 158 184 214 244 279 309 336 363
Med-low 44 75 92 117 150 170 198 230 249 110 150 178 209 248 288 324 355 389 430 460
Med-High 69 102 126 154 178 206 235 274 299 187 230 262 305 337 378 429 463 501 536 573
High 94 133 162 185 216 255 294 321 360 270 319 361 403 440 494 538 580 629 670 718
Factory Default
Cooling
Speed
Low 27 50 69 87 102 127 150 168 192 59 88 116 136 161 194 218 251 272 302 325
Med-low 35 60 80 100 125 150 175 195 225 86 126 154 177 205 242 280 306 345 377 409
Med-High 54 83 107 128 157 184 210 243 263 131 172 203 240 279 318 351 390 426 469 500
High 78 113 137 162 189 221 252 284 317 210 252 291 327 376 413 456 493 529 570 620
– Setting
Cooling
Speed
Low 24 42 65 80 93 116 135 155 173 37 66 89 111 140 163 190 202 239 266 296
Med-low 32 57 75 94 114 136 161 184 205 71 104 128 155 180 208 237 276 302 327 352
Med-High 38 65 85 106 135 158 184 200 233 97 137 166 191 225 264 304 330 367 402 434
High 61 91 118 139 164 196 221 255 276 145 182 220 259 299 333 374 410 449 487 523