BLOWER DATA
G50UH−48C−110 PERFORMANCE
External Static
Air Volume / Watts at Various Blower Speeds
External
Static
Pressure
High Medium−High Medium−Low Low
in. w.g. Pa cfm L/s Watts cfm L/s Watts cfm L/s Watts cfm L/s Watts
0.00 0 2015 950 895 1620 765 780 1340 630 640 1150 545 525
0.05 12 1990 940 870 1615 760 760 1340 630 640 1150 545 525
0.10 25 1965 925 850 1610 760 745 1340 630 640 1150 545 525
0.15 37 1930 910 825 1605 755 725 1335 630 630 1150 545 525
0.20 50 1895 895 805 1600 755 710 1335 630 615 1150 545 525
0.25 62 1860 880 785 1590 750 695 1330 630 605 1150 545 520
0.30 75 1820 860 765 1580 745 675 1330 630 590 1145 540 515
0.40 100 1740 820 725 1530 720 635 1320 625 560 1140 540 490
0.50 125 1665 785 695 1475 695 600 1285 605 525 1120 530 470
0.60 150 1575 745 650 1405 665 555 1230 580 490 1075 505 445
0.70 175 1475 695 610 1310 620 515 1165 550 470 1015 480 415
0.80 200 1350 635 560 1210 570 485 1080 510 430 930 440 380
0.90 225 1210 570 520 1070 505 430 870 410 365 740 350 325
NOTE All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished field provided) in place. Also see Filter Air Resistance table.
G50UH−48C−135 PERFORMANCE
External Static
Air Volume / Watts at Various Blower Speeds
External
Static
Pressure
High Medium−High Medium−Low Low
in. w.g. Pa cfm L/s Watts cfm L/s Watts cfm L/s Watts cfm L/s Watts
0.00 0 2075 980 820 1800 850 710 1425 675 570 1115 525 435
0.05 12 2035 960 805 1785 840 695 1425 670 560 1120 530 435
0.10 25 1990 940 790 1765 835 675 1420 670 545 1125 530 430
0.15 37 1950 920 765 1740 820 660 1410 665 535 1125 530 425
0.20 50 1905 900 745 1715 810 645 1405 665 525 1120 530 420
0.25 62 1865 880 730 1680 795 625 1390 655 515 1115 525 410
0.30 75 1825 860 715 1650 780 610 1375 650 505 1105 520 405
0.40 100 1740 820 680 1585 745 580 1355 640 485 1090 515 390
0.50 125 1640 775 645 1495 705 545 1300 615 455 1050 495 370
0.60 150 1540 730 615 1420 670 515 1225 580 430 1000 470 355
0.70 175 1420 670 575 1310 615 475 1140 535 400 935 440 330
0.80 200 1260 595 520 1155 545 425 1025 485 365 865 410 315
0.90 225 1125 530 495 1010 475 385 880 415 330 750 355 285
NOTE All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished field provided) in place. Also see Filter Air Resistance table.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox G50UHX Series and is the answer not in the manual?

Lennox G50UHX Series Specifications

General IconGeneral
BrandLennox
ModelG50UHX Series
CategoryFurnace
LanguageEnglish

Related product manuals