Page 18
TABLE 5
OUTDOOR TERMINATION KITS AND CORRESPONDING EQUIVALENCIES
UNIT
MODEL
VENT
PIPE
DIA.
(in.)
Vent Pipe Length Equivalency (feet)
Outdoor
Exhaust
Accelera-
tor
(Dia. X
Length)
Outdoor
Exhaust
Acceler-
ator
(Dia. X
Length)
1−1/2"
Concentric
Kit
2"
Concentric
Kit
3"
Concen-
tric Kit
2" Wall
Plate Kit
3" Wall
Plate Kit
2" Wall
Ring
Kit
Flush Mount
Termination
1−1/2" X
12"
2" X 12"
71M80
or
44W92
69M29
or
44W92
60L46
or
44W93
22G44
or
30G28
44J40
or
81J20
15F74
51W11
with
1−1/2
accelera-
tor
51W11
without
1−1/2" ac-
celerator
36B−045
2 4
Not
Allowed
12
Not
Allowed
Not
Allowed
4 4* 4 4
Not
Allowed
2−1/2 5
Not
Allowed
15
Not
Allowed
Not
Allowed
5 5* 5 7****
Not
Allowed
3 7
Not
Allowed
21
Not
Allowed
Not
Allowed
7 7* 7 7
Not
Allowed
4 14
Not
Allowed
42
Not
Allowed
Not
Allowed
14 14* 14
Not
Allowed
Not
Allowed
36B−070
36B−071
2 4
Not
Allowed
12
Not
Allowed
Not
Allowed
4 4* 4 4
Not
Allowed
2−1/2 5
Not
Allowed
15
Not
Allowed
Not
Allowed
5 5* 5 7****
Not
Allowed
3 8
Not
Allowed
24
Not
Allowed
Not
Allowed
8 8* 8 8
Not
Allowed
4 14
Not
Allowed
42
Not
Allowed
Not
Allowed
14 14* 14
Not
Allowed
Not
Allowed
36B−091
60C−090
2
Not
Allowed
1
Not
Allowed
3 3
Not
Allowed
1 1** 4
Not
Allowed
2−1/2
Not
Allowed
2
Not
Allowed
6 6
Not
Allowed
2 2** 7****
Not
Allowed
3
Not
Allowed
2
Not
Allowed
6 6
Not
Allowed
2 2** 8
Not
Allowed
4
Not
Allowed
4
Not
Allowed
12 12
Not
Allowed
4 4**
Not
Allowed
Not
Allowed
60C−110
60C−111
2
Not
Allowed
1
Not
Allowed
3 3
Not
Allowed
1 1**
Not
Allowed
1
2−1/2
Not
Allowed
2
Not
Allowed
6 6
Not
Allowed
2 2***
Not
Allowed
4****
3
Not
Allowed
2
Not
Allowed
6 6
Not
Allowed
2 2***
Not
Allowed
7
4
Not
Allowed
4
Not
Allowed
12 12
Not
Allowed
4 4***
Not
Allowed
Not
Allowed
60D−135
3
Not
Allowed
6
Not
Allowed
Not
Allowed
15
Not
Allowed
6 6***
Not
Allowed
7
4
Not
Allowed
10
Not
Allowed
Not
Allowed
25
Not
Allowed
10 10***
Not
Allowed
Not
Allowed
*Requires field−provided and installed 1−1/2" exhaust accelerator.
**Requires field−provided and installed 2" exhaust accelerator.
***For use only in non−direct vent applications, when snow riser is not required. Re-
quires field−provided and installed 2" exhaust accelerator.
**** Requires field−provided and installed 2"−2−1/2" coupling on G61MPV−36B−045,
G61MPV−36B−070, 071, G61MPV−36B−090,091 and G61MPV−60C−110 furnaces
Termination kits 44W92, 44W93, 30G28 & 81J20 are ULC−636 approved for Cana-
dian Installation.
The 44W92 Concentric kit is provided with a 1−1/2" accelerator which must be
installed on the exhaust outlet when this kit is used with the G61MPV−36B−045,
G61MPV−36B−070 & 071 furnaces.