ELECTRICAL DATA 4-5 TON
Model No. LCA/LGA048
Line voltage data — 60 Hz
208/230v
1 phase
208/230v
3 phase
460v
3 phase
575v
3 phase
Full load amps 2.4 1.3 1.0
Fan Motor
Locked rotor amps 4.7 2.4 1.9
hp 0.75 1.5 0.75 1.5 2 3 0.75 1.5 2 3 0.75 1.5 2 3
Indoor
Output
kW 0.56 1.1 0.56 1.1 1.5 2.2 0.56 1.1 1.5 2.2 0.56 1.1 1.5 2.2
Full load amps 4.6 11.5 4.6 5.7 7.5 10.6 2.3 2.8 3.4 4.8 2.3 2.4 2.7 3.9
Locked rotor amps 10 55 10 40 46.9 66 5.4 20 20.4 26.8 5.4 15 16.2 23.4
Horsepower (W) 1/2 (363)
Optional Power
Full load amps 4.4 1.7
Locked rotor amps 4.7 4.1
Service Outlet (2) 115 volt GFCI (amp rating) 15
LCA/LGA048S MODELS
Rated load amps each 23.4 12.2 7.1 5.8
Locked rotor amps each 110.0 90.0 46.0 37.0
With Exhaust Fan 60 70 35 35 40 40 20 20 20 20 15 15 15 15
size (amps)
Less Exhaust Fan 60 60 30 35 35 40 20 20 20 20 15 15 15 15
With Exhaust Fan 41 48 27 28 30 33 15 15 16 17 13 13 13 14
Circuit Ampacity
Less Exhaust Fan 37 44 23 24 26 29 13 13 14 15 11 11 11 13
LCA/LGA048H MODELS
Rated load amps each 23.7 13.5 7.4 5.8
Locked rotor amps each 129.0 99.0 49.5 40.0
With Exhaust Fan 60 70 40 40 40 45 20 20 20 20 15 15 15 15
size (amps)
Less Exhaust Fan 60 60 35 35 40 40 20 20 20 20 15 15 15 15
With Exhaust Fan 42 48 29 30 32 35 15 16 16 18 13 13 13 14
Circuit Ampacity
Less Exhaust Fan 37 44 24 25 27 30 13 14 14 16 11 11 11 13
Model No. LCA/LGA060
Line voltage data — 60 Hz
208/230v -
1 phase
208/230v
3 phase
460v
3 phase
575v
3 phase
Full load amps 2.4 1.3 1.0
Fan Motor
Locked rotor amps 4.7 2.4 1.9
hp 0.75 1.5 0.75 1.5 2 3 0.75 1.5 2 3 0.75 1.5 2 3
Indoor
Output
kW 0.56 1.1 0.56 1.1 1.5 2.2 0.56 1.1 1.5 2.2 0.56 1.1 1.5 2.2
Full load amps 4.6 11.5 4.6 5.7 7.5 10.6 2.3 2.8 3.4 4.8 2.3 2.4 2.7 3.9
Locked rotor amps 10 55 10 40 46.9 66 5.4 20 20.4 26.8 5.4 15 16.2 23.4
Horsepower (W) 1/2 (363)
Optional Power
Full load amps 4.4 1.7
Locked rotor amps 4.7 4.1
Service Outlet (2) 115 volt GFCI (amp rating) 15
LCA/LGA060S MODELS
Rated load amps each 26.9 16.7 8.6 6.0
Locked rotor amps each 141.0 110.0 55.0 44.0
With Exhaust Fan 70 70 45 50 50 50 20 25 25 25 15 15 15 20
size (amps)
Less Exhaust Fan 60 70 40 45 45 50 20 20 20 25 15 15 15 15
With Exhaust Fan 46 52 33 34 36 39 17 17 18 19 13 13 13 15
Circuit Ampacity
Less Exhaust Fan 41 48 28 29 31 34 15 15 16 17 11 11 12 13
LCA/LGA060H MODELS
Rated load amps each 28.8 17.3 9.0 7.1
Locked rotor amps each 169.0 123.0 62.0 50.0
With Exhaust Fan 70 70 50 50 50 50 25 25 25 25 20 20 20 20
size (amps)
Less Exhaust Fan 70 70 45 45 45 50 20 20 20 25 15 15 15 20
With Exhaust Fan 48 55 34 35 36 40 17 18 18 20 14 14 15 16
Circuit Ampacity
Less Exhaust Fan 44 50 29 30 32 35 15 16 16 18 13 13 13 14
*Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE — Extremes of operating range are plus and minus 10 % of line voltage.
NOTE — Where current does not exceed 100 amps, HACR type circuit breaker may be used in place of fuse (U.S. only).