OPTIONS / ACCESSORIES
Item Description
Model
Number
Catalog
Number
Unit Model No.
180U 240U 300U
COOLING SYSTEM
Condensate Drain Trap PVC - C1TRAP20AD2 76W26OXO
XO
X
Copper - C1TRAP10AD2 76W27OXO
XO
X
Corrosion Protection FactoryO
OO
E1SNSR71AD1 68W88OXO
XO
X
Refrigerant Type R-410A
OOO
HEATING SYSTEM
Bottom Gas Piping Kit C1GPKT01C-1 85M31OXO
XO
X
Combustion Air Intake Extensions (order two) LTACAIK10/15 89L97X
XX
Gas Heat Input Low - 169,000 Btuh FactoryO
Standard - 260,000 Btuh FactoryO
OO
Medium - 360,000 Btuh FactoryO
OO
High - 480,000 Btuh Factory
OOO
Low Temperature Vestibule Heater 208/230V-3ph - C1LTVH10C-2Y 13X66OXO
XO
X
460V-3ph - C1LTVH10C-2G 13X67OXO
XO
X
575V-3ph - C1LTVH10C-2J 13X68OXO
XO
X
LPG/Propane Conversion Kits
(Order 2 kits)
Low Heat - C1PROP25C11 14N28X
Standard Heat - C1PROP25C1114N28
XXX
Medium Heat - C1PROP26C1114N29X
XX
High Heat - C1PROP27C11 14N30
XXX
Stainless Steel Heat Exchanger Factory
OOO
Vertical Vent Extension Kit (Order two kits) C1EXTN2021 42W16
XXX
BLOWER - SUPPLY AIR
Blower MSAV (multi-stage air volume) blower option (With VFD Bypass Control) Factory
OOO
MSAV (multi-stage air volume) blower option (Without VFD Bypass Control) Factory
OOO
Motors - MSAV (multi-
stage air volume)
FactoryO
Factory
OOO
Factory
OOO
Factor
yO
O
Drive Kits
See Blower Data Tables for usage and
selection
Kit #1 535-725 rpmFactory O
mpr 569-017 2# tiKFactory O
Kit #3 685-856 rpmFactory
OOO
Kit #4 850-1045 rpmFactory
OOO
Kit #5 945-1185 rpmFactory
OOO
Kit #6 850-1045 rpmFactory
OOO
Kit #7 945-1185 rpmFactory
OOO
Kit #8 1045-1285 rpmFactory
OOO
Kit #10 1045-1285 rpmFactory
OO
Kit #11 1135-1365 rpmFactory
OO
Blower Belt Auto-Tensioner Factory
OOO
CONTROLS
Blower Proving Switch C1SNSR35FF153W65 OX OX OX
Commercial
Controls
Prodigy
®
Control System - BACnet
®
Module - C0CTRL60AE1L 59W51 OX OX OX
Prodigy
®
Control System - LonTalk
®
Module - C0CTRL65FF154W27 OX OX OX
Novar
®
LSEFactory OOO
L Connection
®
Building Automation System - - -X
XX
Dirty Filter Switch E1SNSR55C-1 53W68OXO
XO
X
Fresh Air Tempering C1SNSR75AD158W63 OX OX OX
General Purpose Control KitE1GPBK30C1 13J78X
XX
Smoke Detector - Supply or Return (Power board and one sensor)C1SNSR44C-1 83W40OXO
XO
X
Smoke Detector - Supply and Return (Power board and two sensors) C1SNSR43C-183W41 OX OX OX
X = Field Installed

Other manuals for Lennox LGH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox LGH Series and is the answer not in the manual?

Lennox LGH Series Specifications

General IconGeneral
BrandLennox
ModelLGH Series
CategoryAir Handlers
LanguageEnglish

Related product manuals