UNIT INFORMATIONUNIT INFORMATION
Service Literature
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause property damage,
personal injury or loss of life. Installation and service
must be performed by a licensed professional HVAC
installer or equivalent, service agency, or the gas
supplier
CAUTION
As with any mechanical equipment, contact with
sharp sheet metal edges can result in personal
injury. Take care while handling this equipment and
wear gloves and protective clothing.
Table of Contents
Options / Accessories . . . . . . . . . . . . . . . . . . . . . Page 2

Blower Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 8
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11
Parts Arrangement . . . . . . . . . . . . . . . . . . . . . . . Page 13
I-Unit Components . . . . . . . . . . . . . . . . . . . . . . . Page 14
II-Placement and Installation . . . . . . . . . . . . . . . Page 29
III-Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 29
IV-Start Up - Operation . . . . . . . . . . . . . . . . . . . . Page 34
V-System Service Checks . . . . . . . . . . . . . . . . Page 36
VI-Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . Page 39
VII-Accessories . . . . . . . . . . . . . . . . . . . . . . . Page 39
VIII-Direct Drive Supply Air Blower . . . . . . . . . . Page 49


WARNING
To prevent serious injury or death:
1- Lock-out/tag-out before performing maintenance.
2- If system power is required (e.g., smoke detector
maintenance), disable power to blower, remove
fan belt where applicable, and ensure all
controllers and thermostats are set to the “OFF”
position before performing maintenance.
3- Always keep hands, hair, clothing, jewelry, tools,
etc., away from moving parts.
       
(CTO) with a wide selection of factory-installed options.

         
sections are designed with aluminized steel tube heat ex-
changers with stainless steel as an option.

are equipped with two compressors.
All models are equipped with direct drive blowers. The
blower will operate at lower speeds when demand is low
and increase to higher speeds when demand is high. The
following examples show the model numbers of tenton
units with all available blower options:

LGT12w are equipped with all aluminum condenser
coils with one two stage scroll compressor and one


        
nameplate. Operating pressures and pressure switch set-
-

󰀨-
ent energy management thermostat control systems with
-
tions connect to the unit with jack plugs. When ”plugged
in” the controls become an integral part of the unit wiring.
Information contained in this manual is intended for use

subject to change. Procedures outlined in this manual are
presented as a recommendation only and do not super-
sede or replace local or state codes.

four cables to the holes located in the unit base rail (two
holes at each corner). Refer to the installation instructions
for the proper rigging technique.
LGT SERIES
7.5 to 12.5 ton

LGT092H through 150H
Question and Answer IconNeed help?

Do you have a question about the Lennox LGT Series and is the answer not in the manual?

Lennox LGT Series Specifications

General IconGeneral
Product TypeAir Handler
AirflowUp to 2000 CFM
Cooling CapacityUp to 5 Tons
Motor TypeECM
Voltage208/230V
ConfigurationUpflow, Downflow, Horizontal
SeriesLGT Series

Summary

SPECIFICATIONS

General Data

Tonnage, efficiency, model numbers, and performance specs.

Gas Heating

Performance data for gas heating stages.

I-UNIT COMPONENTS

Control Box Components

Identification of components within the control box.

Temperature Sensors

Description and function of various temperature sensors.

IV-START-UP - OPERATION

A-Preliminary and Seasonal Checks

Essential pre-operation inspection steps.

C-Heating Start-up

Step-by-step procedure for starting the heating function.

V-SYSTEMS SERVICE CHECKS

A-Heating System Service Checks

Procedures for checking the heating system's operation.

3-Testing Gas Supply Pressure

Method for verifying gas supply pressure.

VI-MAINTENANCE

A-Filters

Routine checks and replacement of air filters.

D-Evaporator Coil

Instructions for inspecting and cleaning the evaporator coil.