78
Installation and Maintenance
Service Manual
ProcedureSteps
1.Remove cable cross plate 2 and valve cover
3.Remove front grille
2.Remove top cover
Remove connection screws connecting the
top cover plate with the front panel and the
right side plate,and then remove the top
cover.
Remove connection screws between the
front grille and the front panel. Then remove
the front grille.
top cover
front grille
screw
Cable Cross Plate 2
Valve Cover
Remove 3 connection screw fixing small
cable cross plate 2 and then remove the
cable cross plate 2.
Remove 1 connection screw fixing valve cover
and then remove the valve cover.
LI012CO-210P432
NOTE: This models haven’t 4-way valve assy.
11.2 Removal Procedure of Outdoor Unit
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.