When mounting the outdoor unit on a roof, be
sure the roof will support the unit’s weight.
Properly selected isolation is recommended to
prevent sound or vibration transmission to the
building structure.
Maximum line length = 100 feet.
Maximum vertical length = 50 feet.
Compressor crankcase heat is required for line
lengths over 50 feet.
Use only the line diameters indicated in Table
Such as the connecting tube is more than 60 feet,
does not use large Suction line than recommend.
5.1.
Section 2. Unit Location Considerations
2.1 Unit Dimensions
2.2 Refrigerant Piping Limits
Unit Dimensions
Models H x W x L(Inches)
24/36
48/60
24-15/16 x 29-1/8 x 29-1/8
33-3/16 x 29-1/8 x 29-1/8
Standard Line
Set 100 Max
Line Length
50’ Max
Line Lift
The unit’s weight values is on the carton box.