EasyManua.ls Logo

Lennox LRP14GE30 User Manual

Lennox LRP14GE30
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
WARNING
Electric Shock Hazard. Can cause injury or
death. Unit must be properly grounded in
accordance with national and local codes.
Line voltage is present at all components when
unit is not in operation on units with single-
pole contactors. Disconnect all remote electric
power supplies before opening access panel.
Unit may have multiple power supplies.
LRP14HP/AC/GE/GN
LRP16GE/HP
Table of Contents
Specications – LRP14HP .............................................2
Specications – LRP14AC ............................................3
Specications – LRP14GE / LRP14GX ......................... 4
Specications – LRP14GN ............................................ 5
Specications – LRP16GE / LRP16GX ......................... 6
Specications – LRP16HP ............................................7
Electric Heat Capacities LRP14HP and AC Models
LRP16HP .......................................................................8
Gas Heat Capacities – LRP14GE Only ......................... 8
Gas Heat Capacities – LRP16GE Only ......................... 8
Gas Heat Capacities – LRP14GN Only .........................8
Electrical .......................................................................9
Typical Parts Arrangement ..........................................16
Unit Applications ..........................................................18
Blower Data – LRP14HP .............................................23
Blower Data – LRP14AC ............................................. 24
Blower Data – LRP14GE / LRP14GX...........................25
Blower Data – LRP14GN..............................................26
Blower Data – LRP16GE / LRP16GX...........................27
Blower Data – LRP16HP ..............................................28
Wiring Diagrams and Sequence of Operation .............. 35
LRP14GN – Heating Components and Operation........46
Service Literature
UNIT INFORMATION
Corp. 100032
October 7, 2021
LRP14HP/LRP14AC/LRP14GE/LRP14GN/LRP16GE/LRP16HP SERIES UNITS
The LRP14/16 series packaged units are available in siz-
es ranging from 2 through 5 tons (7.0 through 17.6 kW).
The LRP14/16 unit is designed for HFC-410A refrigerant
and for outdoor residential use only. Units can be installed
at ground level or on rooftops. The LRP14 units utilize a
scroll compressor. LRP16GE/GX/HP units utilize a two-
stage compressor. Information contained in this manual is
intended for use by qualied service technicians only. All
specications are subject to change. Procedures outlined
in this manual are presented as a recommendation only
and do not supersede or replace local or state codes.
Question and Answer IconNeed help?

Do you have a question about the Lennox LRP14GE30 and is the answer not in the manual?

Lennox LRP14GE30 Specifications

General IconGeneral
BrandLennox
ModelLRP14GE30
CategoryFurnace
LanguageEnglish

Summary

Model Specifications

LRP14HP Specifications

Detailed specifications for the LRP14HP model series.

LRP14AC Specifications

Detailed specifications for the LRP14AC model series.

LRP14GE/GX Specifications

Detailed specifications for the LRP14GE/GX model series.

LRP14GN Specifications

Detailed specifications for the LRP14GN model series.

LRP16GE/GX Specifications

Detailed specifications for the LRP16GE/GX model series.

LRP16HP Specifications

Detailed specifications for the LRP16HP model series.

Performance Data

Unit Applications and Components

Blower Control and Adjustment

Defrost Control System

Wiring Diagrams

Heat Pump Wiring Schematics

Wiring diagrams for LRP14HP and LRP16HP heat pump units.

AC/Gas Unit Wiring Schematics

Wiring diagrams for LRP14AC, GE, GN units.

LRP16GE/HP Wiring Schematics

Wiring diagrams for LRP16GE and LRP16HP units.

Sequences of Operation

Related product manuals