EasyManua.ls Logo

Lennox LRP14HP60 User Manual

Lennox LRP14HP60
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Page 1
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
WARNING
Electric Shock Hazard. Can cause injury or
death. Unit must be properly grounded in
accordance with national and local codes.
Line voltage is present at all components when
unit is not in operation on units with single-
pole contactors. Disconnect all remote electric
power supplies before opening access panel.
Unit may have multiple power supplies.
LRP14HP/AC/GE/GN
LRP16GE/HP
Table of Contents
Specications – LRP14HP .............................................2
Specications – LRP14AC ............................................3
Specications – LRP14GE / LRP14GX ......................... 4
Specications – LRP14GN ............................................ 5
Specications – LRP16GE / LRP16GX ......................... 6
Specications – LRP16HP ............................................7
Electric Heat Capacities LRP14HP and AC Models
LRP16HP .......................................................................8
Gas Heat Capacities – LRP14GE Only ......................... 8
Gas Heat Capacities – LRP16GE Only ......................... 8
Gas Heat Capacities – LRP14GN Only .........................8
Electrical .......................................................................9
Typical Parts Arrangement ..........................................16
Unit Applications ..........................................................18
Blower Data – LRP14HP .............................................23
Blower Data – LRP14AC ............................................. 24
Blower Data – LRP14GE / LRP14GX...........................25
Blower Data – LRP14GN..............................................26
Blower Data – LRP16GE / LRP16GX...........................27
Blower Data – LRP16HP ..............................................28
Wiring Diagrams and Sequence of Operation .............. 35
LRP14GN – Heating Components and Operation........46
Service Literature
UNIT INFORMATION
Corp. 100032
October 7, 2021
LRP14HP/LRP14AC/LRP14GE/LRP14GN/LRP16GE/LRP16HP SERIES UNITS
The LRP14/16 series packaged units are available in siz-
es ranging from 2 through 5 tons (7.0 through 17.6 kW).
The LRP14/16 unit is designed for HFC-410A refrigerant
and for outdoor residential use only. Units can be installed
at ground level or on rooftops. The LRP14 units utilize a
scroll compressor. LRP16GE/GX/HP units utilize a two-
stage compressor. Information contained in this manual is
intended for use by qualied service technicians only. All
specications are subject to change. Procedures outlined
in this manual are presented as a recommendation only
and do not supersede or replace local or state codes.
Question and Answer IconNeed help?

Do you have a question about the Lennox LRP14HP60 and is the answer not in the manual?

Lennox LRP14HP60 Specifications

General IconGeneral
BrandLennox
ModelLRP14HP60
CategoryFurnace
LanguageEnglish

Summary

Unit Information and Safety

General Safety Warnings

Combines all safety warnings, cautions, and important notes on the page.

Specifications – LRP14HP

Specifications – LRP14AC

Specifications – LRP14GE / LRP14GX

Specifications – LRP14GN

Specifications – LRP16GE / LRP16GX

Specifications – LRP16HP

Heat Capacities

Electric Heat Data – LRP14HP Only

Electric Heat Data – LRP14AC Only

Electrical Data – LRP14GE Only

Electrical Data – LRP16GE Only

Electrical Data – LRP14GN

Electric Heat Data – LRP16HP Only

High Altitude Derate

Unit Applications and Components

Electronic Ignition Operation

Ignition Control Diagnostics

Safety Warnings

Electrical shock hazard warning for servicing.

Blower Control Systems

Defrost Control Operation

Component Details & Safety

Compressor Safety Warnings

Electrical shock hazard warning for compressors.

System Components and Electric Heat

Control System Diagnostics

Performance Values & Maintenance

Cooling/heating performance values and maintenance.

System Maintenance Procedures

Gas Checks and Pressure Measurement

Gas leak checks, supply pressure, and manifold pressure.

Wiring Diagrams and Sequence of Operation

LRP14HP Unit Wiring Diagram

Wiring diagram for LRP14HP unit.

Wiring Diagrams

LRP14AC Unit Wiring Diagram

Wiring diagram for LRP14AC unit.

LRP14GE Unit Wiring Diagram

Wiring diagram for LRP14GE unit.

LRP16GE Wiring Diagram

Wiring diagram for LRP16GE unit.

LRP16GE Unit Wiring – Single Phase

Single-phase wiring diagram for LRP16GE.

LRP16HP Wiring Diagram

Wiring diagram for LRP16HP unit.

LRP16HP Unit Wiring – Single Phase

Single-phase wiring diagram for LRP16HP.

A-PHK Electric Heat Wiring Diagram

B-PHK Electric Heat Wiring Diagram - Older Models

Sequence of Operation

Single-Stage Compressor Operation

Operation sequence for single-stage compressors.

Gas Heat Operation

Operation sequence for gas heat.

Two-Stage Compressor Operation

Operation sequence for two-stage compressors.

LRP14GN – Heating Components and Operation

Manifold Pressure Measurement