ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 101
AHRI SYSTEM MATCHES - SOUTHWEST REGIONS -018, -024, -030, 036, -042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-036-230 TXV 34400 15.5 12.5 CH33-42B EL180UH090XE48B 9143122
ML14XC1-036-230 TXV 34200 14.5 12.2 CH33-42B EL195UH045XE36B 9143123
ML14XC1-036-230 TXV 34000 15.1 12.5 CH33-42B EL195UH070XE36B 9143124
ML14XC1-036-230 TXV 34200 14.5 12.2 CH33-42B EL296UH045XE36B 9143125
ML14XC1-036-230 TXV 34400 15.1 12.5 CH33-42B EL296UH045XV36B 9143126
ML14XC1-036-230 TXV 34000 15.1 12.5 CH33-42B EL296UH070XE36B 9143127
ML14XC1-036-230 TXV 34400 15.1 12.5 CH33-42B EL296UH070XV36B 9143128
ML14XC1-036-230 TXV 34600 16 13 CH33-42B SL280UH090V36B 9143129
ML14XC1-036-230 TXV 34600 15.5 12.5 CH33-42B SL280UH090V48B 9143130
ML14XC1-036-230 TXV 34600 15.5 12.5 CH33-42B SL280UH090XV48B 9143131
ML14XC1-036-230 TXV 34400 15.1 12.5 CH33-42B SLP98UH070XV36B 9143132
ML14XC1-036-230 TXV 35600 16 13 CH33-43B EL180UH070E36B 9143133
ML14XC1-036-230 TXV 35600 16 13 CH33-43B EL180UH070XE36B 9143134
ML14XC1-036-230 TXV 35800 16 13 CH33-43B EL180UH090E48B 9143135
ML14XC1-036-230 TXV 35800 16 13 CH33-43B EL180UH090XE48B 9143136
ML14XC1-036-230 TXV 35600 15.5 12.5 CH33-43B EL195UH045XE36B 9143137
ML14XC1-036-230 TXV 35400 16 13 CH33-43B EL195UH070XE36B 9143138
ML14XC1-036-230 TXV 35600 15.5 12.5 CH33-43B EL296UH045XE36B 9143139
ML14XC1-036-230 TXV 35800 16 13 CH33-43B EL296UH045XV36B 9143140
ML14XC1-036-230 TXV 35400 16 13 CH33-43B EL296UH070XE36B 9143141
ML14XC1-036-230 TXV 35800 16 13 CH33-43B EL296UH070XV36B 9143142
ML14XC1-036-230 TXV 36000 16 13 CH33-43B SL280UH090V36B 9143143
ML14XC1-036-230 TXV 36000 16 13 CH33-43B SL280UH090V48B 9143144
ML14XC1-036-230 TXV 36000 16 13 CH33-43B SL280UH090XV48B 9143145
ML14XC1-036-230 TXV 35800 16 13 CH33-43B SLP98UH070XV36B 9143146
ML14XC1-036-230 TXV 35400 15.1 12.5 CH33-43B 9143148
ML14XC1-036-230 TXV 35600 16 13 CH33-43C EL180UH090E60C 9143149
ML14XC1-036-230 TXV 35400 16 13 CH33-43C EL180UH110E60C 9143150
ML14XC1-036-230 TXV 35400 16 13 CH33-43C EL180UH110XE60C 9143151
ML14XC1-036-230 TXV 35400 16 13 CH33-43C EL195UH090XE48C 9143152
ML14XC1-036-230 TXV 35600 16 13 CH33-43C EL195UH110XE60C 9143153
ML14XC1-036-230 TXV 35400 16 13 CH33-43C EL296UH090XE48C 9143154
ML14XC1-036-230 TXV 35400 16 13 CH33-43C EL296UH090XV36C 9143155
ML14XC1-036-230 TXV 35200 16 13 CH33-43C EL296UH090XV48C 9143156
ML14XC1-036-230 TXV 35600 16 13 CH33-43C EL296UH110XE60C 9143157
ML14XC1-036-230 TXV 35400 16 13 CH33-43C EL296UH110XV48C 9143158
ML14XC1-036-230 TXV 35800 16 13 CH33-43C EL296UH110XV60C 9143159
ML14XC1-036-230 TXV 35800 16 13 CH33-43C SL280UH090V60C 9143160
ML14XC1-036-230 TXV 35800 16 13 CH33-43C SL280UH090XV60C 9143161
ML14XC1-036-230 TXV 35600 16 13 CH33-43C SL280UH110V60C 9143162
ML14XC1-036-230 TXV 35600 16 13 CH33-43C SL280UH110XV60C 9143163
ML14XC1-036-230 TXV 35400 16 13 CH33-43C SLP98UH090XV36C 9143164
ML14XC1-036-230 TXV 35200 16 13 CH33-43C SLP98UH090XV48C 9143165
ML14XC1-036-230 TXV 35800 16 13 CH33-43C SLP98UH110XV60C 9143166
ML14XC1-036-230 TXV 34600 16 13 CH33-44/48B EL180UH070E36B 9143167
ML14XC1-036-230 TXV 34600 16 13 CH33-44/48B EL180UH070XE36B 9143168
ML14XC1-036-230 TXV 35000 16 13 CH33-44/48B EL180UH090E48B 9143169
ML14XC1-036-230 TXV 35000 16 13 CH33-44/48B EL180UH090XE48B 9143170
ML14XC1-036-230 TXV 34800 15.1 12.5 CH33-44/48B EL195UH045XE36B 9143171
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.