THIS MANUAL MUST BE LEFT WITH THE
HOMEOWNER FOR FUTURE REFERENCE
General
This ML17XC1 outdoor air conditioner with all-aluminum
coil is designed for use with HFC-410A refrigerant only.
This unit must be installed with an approved indoor air han-
dler or coil. For AHRI Certied system match-ups and ex-
panded ratings, visit www.LennoxPros.com.
These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
having jurisdiction before installation.
NOTICE!
Charging information is given on the charging
procedure sticker on the unit access panel. For more in-
depth information, consult the Installation and Service
Procedures manual on LennoxPros.com or through the
Technical Support department at 800-453-6669.
INSTALLATION
INSTRUCTIONS
AIR CONDITIONER
508254-01
4/2022
Merit
®
Series ML17XC1 Units
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, or service agency.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
IMPORTANT: Special procedures are required for clean-
ing the all-aluminum coil in this unit. See page 15 in this
instruction for information.
STEP 1 – SETTING THE UNIT – Clearances
NOTES -
Service clearance of 30 in. (762 mm) must be maintained on one of
the sides adjacent to the control box.
Clearance to one of the other three sides must be 36 in. (914 mm).
Clearance to one of the remaining two sides may be 12 in. (305
mm) and the final side may be 6 in. (152 mm).
A clearance of 24 in. must be maintained between two units.
48 in. (1219 mm) clearance required on top of unit.
See
NOTES
See NOTES
See NOTES
See
NOTES
CONTROL
BOX
NOTICE: Specific applications may require adjustment of the listed installation clearances to provide protection for
the unit from physical damage or to avoid conditions which limit operating efficiency. (Example: Clearances may
have to be increased to prevent snow or ice from falling on the top of the unit. Additional clearances may also be
required to prevent air recirculation when the unit is installed under a deck or in another tight space.)
FIGURE 1
Question and Answer IconNeed help?

Do you have a question about the Lennox Merit ML17XC1-047-230A and is the answer not in the manual?

Lennox Merit ML17XC1-047-230A Specifications

General IconGeneral
BrandLennox
ModelMerit ML17XC1-047-230A
CategoryAir Conditioner
LanguageEnglish

Summary

STEP 2 - REFRIGERANT PIPING – Flushing Existing Line Set & Indoor Coil

Importance of Line Set and Coil Flushing

Explains why flushing is necessary for units with mineral oil or older coils.

Refrigerant Handling and POE Oil Precautions

Warnings related to handling refrigerant, POE oils, and nitrogen.

Liquid Line Filter Drier Installation

Instructions for installing the liquid line filter drier for a clean system.

STEP 2 – REFRIGERANT PIPING – Removing Existing Indoor Metering Device

System Flushing Procedure

Procedure for flushing the line set and indoor coil with refrigerant.

STEP 2 – REFRIGERANT PIPING – Brazing Procedures

Brazing Safety and Precautions

Safety precautions for handling brazing alloys, flux, and fire hazards.

STEP 2 – REFRIGERANT PIPING – Brazing Procedures (Continued)

Line Set Brazing and Cooling Steps

Instructions for brazing the line set to service valves and cooling the joint.

STEP 2 – REFRIGERANT PIPING – Install Indoor Expansion Valve

Indoor Expansion Valve Installation Steps

Detailed steps for installing the expansion valve unit at the indoor coil.

STEP 3 - LEAK TEST AND EVACUATION

System Leak Testing Procedure

Procedure for connecting gauges and testing the system for leaks.

STEP 3 – LEAK TEST AND EVACUATION (Continued)

System Evacuation Process

Steps for evacuating the line set and indoor unit to specific micron levels.

Deep Vacuum Operation Hazards

Warnings regarding deep vacuum operation and potential compressor damage.

STEP 4 – ELECTRICAL – Circuit Sizing and Wire Routing

Electrical Safety and Grounding

Warnings about electric shock, wire types, ESD, and grounding.

Checking and Adding System Charge

Refrigerant Charge Calculation and Adjustment

How to calculate additional refrigerant charge based on line set length.

ML17XC1 Start-Up and Performance Checklist

System Refrigerant Charge Verification

Verifying system subcooling and approach temperatures for proper refrigerant charge.