EasyManuals Logo

Lennox MERIT ML14XC1 User Manual

Lennox MERIT ML14XC1
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 12
AHRI SYSTEM MATCHES - ALL REGIONS -041, -047, -048, -059, -060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-041-230 TXV 37200 16 13 CBX25UH-042 9144729
ML14XC1-041-230 TXV 38000 16 13 CBX25UH-048 9144730
ML14XC1-041-230 TXV 38000 17 13.5 CBX25UHV-042 9144731
ML14XC1-041-230 TXV 38500 17 13.5 CBX25UHV-048 9144732
ML14XC1-041-230 TXV 38500 16 13.5 CBX27UH-048 9144733
ML14XC1-041-230 TXV 38000 16 13 CBX32MV-048 9144734
ML14XC1-041-230 TXV 38000 16 13 CBX40UHV-048 9144735
ML14XC1-041-230 TXV 36400 16 13 CH23-51 EL180UH090E60C 9144736
ML14XC1-041-230 TXV 36600 16 13 CH23-51 SL280UH090V60C 9144737
ML14XC1-041-230 TXV 37000 16 13.5 CH23-65 EL180UH090E60C 9144738
ML14XC1-041-230 TXV 37000 16 13 CH23-65 SL280UH090V60C 9144739
ML14XC1-041-230 TXV 38000 16 13 CH33-43 EL180UH090E60C 9144745
ML14XC1-041-230 TXV 38000 16 13 CH33-43B EL180UH090E48B 9144740
ML14XC1-041-230 TXV 38000 16 13 CH33-43B EL180UH090XE48B 9144741
ML14XC1-041-230 TXV 38000 16 13 CH33-43B SL280UH090V36B 9144742
ML14XC1-041-230 TXV 38000 16 13 CH33-43B SL280UH090V48B 9144743
ML14XC1-041-230 TXV 38000 16 13 CH33-43B SL280UH090XV48B 9144744
ML14XC1-041-230 TXV 38000 16 13 CH33-43C EL180UH110E60C 9144746
ML14XC1-041-230 TXV 38000 16 13 CH33-43C EL180UH110XE60C 9144747
ML14XC1-041-230 TXV 38000 16 13 CH33-43C EL195UH090XE48C 9144748
ML14XC1-041-230 TXV 37600 16 13.5 CH33-43C EL195UH110XE60C 9144749
ML14XC1-041-230 TXV 38000 16 13 CH33-43C EL296UH090XE48C 9144750
ML14XC1-041-230 TXV 38000 16 13 CH33-43C EL296UH090XV36C 9144751
ML14XC1-041-230 TXV 38000 16 13 CH33-43C EL296UH090XV48C 9144752
ML14XC1-041-230 TXV 38000 16 13 CH33-43C EL296UH090XV60C 9144753
ML14XC1-041-230 TXV 37600 16 13.5 CH33-43C EL296UH110XE60C 9144754
ML14XC1-041-230 TXV 38500 16 13.5 CH33-43C EL296UH110XV60C 9144755
ML14XC1-041-230 TXV 38500 16 13.5 CH33-43C SL280UH090V60C 9144756
ML14XC1-041-230 TXV 38500 16 13.5 CH33-43C SL280UH090XV60C 9144757
ML14XC1-041-230 TXV 38000 16 13 CH33-43C SL280UH110V60C 9144758
ML14XC1-041-230 TXV 38000 16 13 CH33-43C SL280UH110XV60C 9144759
ML14XC1-041-230 TXV 38000 16 13 CH33-43C SLP98UH090XV36C 9144760
ML14XC1-041-230 TXV 38000 16 13 CH33-43C SLP98UH090XV48C 9144761
ML14XC1-041-230 TXV 38000 16 13 CH33-43C SLP98UH090XV60C 9144762
ML14XC1-041-230 TXV 38500 16 13.5 CH33-43C SLP98UH110XV60C 9144763
ML14XC1-041-230 TXV 37800 16 13 CH33-44/48B EL180UH090E48B 9144764
ML14XC1-041-230 TXV 37800 16 13 CH33-44/48B EL180UH090XE48B 9144765
ML14XC1-041-230 TXV 38000 16 13 CH33-48C EL180UH090E60C 9144766
ML14XC1-041-230 TXV 37800 16 13 CH33-48C EL180UH110E60C 9144767
ML14XC1-041-230 TXV 37800 16 13 CH33-48C EL180UH110XE60C 9144768
ML14XC1-041-230 TXV 37600 16 13 CH33-48C EL195UH090XE48C 9144769
ML14XC1-041-230 TXV 37400 16 13 CH33-48C EL195UH110XE60C 9144770
ML14XC1-041-230 TXV 37600 16 13 CH33-48C EL296UH090XE48C 9144771
ML14XC1-041-230 TXV 37600 16 13 CH33-48C EL296UH090XV36C 9144772
ML14XC1-041-230 TXV 37800 16 13 CH33-48C EL296UH090XV48C 9144773
ML14XC1-041-230 TXV 37400 16 13 CH33-48C EL296UH110XE60C 9144774
ML14XC1-041-230 TXV 37600 16 13 CH33-48C SLP98UH090XV36C 9144775
ML14XC1-041-230 TXV 37800 16 13 CH33-48C SLP98UH090XV48C 9144776
ML14XC1-041-230 TXV 38500 17 13.5 CH33-49 EL180UH090E60C 9144777
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox MERIT ML14XC1 and is the answer not in the manual?

Lennox MERIT ML14XC1 Specifications

General IconGeneral
Compressor TypeSingle-stage
RefrigerantR-410A
Energy Star CertifiedNo
Cooling Capacity (BTU/h)18, 000 - 60, 000
Operating Voltage (VAC)208/230
Unit Weight (lbs)Varies by model
Dimensions (H x W x D, inches)Varies by model
Cooling Capacity1.5 to 5 tons
Warranty5-Year Limited Warranty on covered components