ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 21
AHRI SYSTEM MATCHES - ALL REGIONS -041, -047, -048, -059, -060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-047-230 TXV 48000 16 13 CX35-60C SL280UH090V60C 9146515
ML14XC1-047-230 TXV 48000 16 13 CX35-60C SL280UH090XV60C 9146516
ML14XC1-047-230 TXV 48000 16 13 CX35-60C SL280UH110V60C 9146517
ML14XC1-047-230 TXV 48000 16 13 CX35-60C SL280UH110XV60C 9146518
ML14XC1-047-230 TXV 48000 15.5 12.5 CX35-60C SLP98UH090XV48C 9146519
ML14XC1-047-230 TXV 48000 15.5 12.5 CX35-60C SLP98UH090XV60C 9146520
ML14XC1-047-230 TXV 48000 15.5 12.5 CX35-60C SLP98UH110XV60C 9146521
ML14XC1-047-230 TXV 48000 15.1 12.5 CX35-60C 9146522
ML14XC1-047-230 TXV 48000 16 13 CX35-60D EL180UH135E60D 9146523
ML14XC1-047-230 TXV 47500 15.5 12.5 CX35-60D EL195UH135XE60D 9146524
ML14XC1-047-230 TXV 47500 15.5 12.5 CX35-60D EL296UH135XE60D 9146525
ML14XC1-047-230 TXV 47500 15.5 12.5 CX35-60D SL280UH135V60D 9146526
ML14XC1-047-230 TXV 48000 15.5 12.5 CX35-60D SLP98UH135XV60D 10040423
ML14XC1-047-230 TXV 47000 14.5 12.2 CX35-60D 9146528
ML14XC1-047-230 TXV 47500 15.1 12.5 CX38-62C 10552471
ML14XC1-048-230 TXV 46000 14.5 12.2 C35-48B EL180UH090E48B 9145115
ML14XC1-048-230 TXV 46000 14.5 12.2 C35-48B EL180UH090XE48B 9145116
ML14XC1-048-230 TXV 46000 14.5 12.5 C35-48C EL180UH090E60C 9145117
ML14XC1-048-230 TXV 46000 14.5 12.5 C35-48C EL180UH110E60C 9145118
ML14XC1-048-230 TXV 46000 14.5 12.5 C35-48C EL180UH110XE60C 9145119
ML14XC1-048-230 TXV 46000 14.5 12.5 C35-48C EL195UH090XE48C 9145120
ML14XC1-048-230 TXV 46000 14.5 12.5 C35-48C EL195UH110XE60C 9145121
ML14XC1-048-230 TXV 46000 14.5 12.5 C35-48C EL296UH090XE48C 9145122
ML14XC1-048-230 TXV 46500 14.5 12.2 C35-48C EL296UH090XV48C 9145123
ML14XC1-048-230 TXV 46500 14.5 12.5 C35-48C EL296UH090XV60C 9145124
ML14XC1-048-230 TXV 46000 14.5 12.5 C35-48C EL296UH110XE60C 9145125
ML14XC1-048-230 TXV 46000 14.5 12.5 C35-48C EL296UH110XV48C 9145126
ML14XC1-048-230 TXV 46500 14.5 12.5 C35-48C EL296UH110XV60C 9145127
ML14XC1-048-230 TXV 46500 14.5 12.5 C35-48C SL280UH090V60C 9145128
ML14XC1-048-230 TXV 46500 14.5 12.5 C35-48C SL280UH090XV60C 9145129
ML14XC1-048-230 TXV 46500 14.5 12.5 C35-48C SL280UH110V60C 9145130
ML14XC1-048-230 TXV 46500 14.5 12.5 C35-48C SL280UH110XV60C 9145131
ML14XC1-048-230 TXV 46500 14.5 12.2 C35-48C SLP98UH090XV48C 9145132
ML14XC1-048-230 TXV 46500 14.5 12.5 C35-48C SLP98UH090XV60C 9145133
ML14XC1-048-230 TXV 46500 14.5 12.5 C35-48C SLP98UH110XV60C 9145134
ML14XC1-048-230 TXV 47000 15.1 12.5 C35-49C EL180UH090E60C 9145135
ML14XC1-048-230 TXV 47000 15.1 12.5 C35-49C EL180UH110E60C 9145136
ML14XC1-048-230 TXV 47000 15.1 12.5 C35-49C EL180UH110XE60C 9145137
ML14XC1-048-230 TXV 47000 14.5 12.5 C35-49C EL195UH090XE48C 9145138
ML14XC1-048-230 TXV 47000 15.1 12.5 C35-49C EL195UH110XE60C 9145139
ML14XC1-048-230 TXV 47000 14.5 12.5 C35-49C EL296UH090XE48C 9145140
ML14XC1-048-230 TXV 47000 14.5 12.5 C35-49C EL296UH090XV48C 9145141
ML14XC1-048-230 TXV 47000 14.5 12.5 C35-49C EL296UH090XV60C 9145142
ML14XC1-048-230 TXV 47000 15.1 12.5 C35-49C EL296UH110XE60C 9145143
ML14XC1-048-230 TXV 47000 14.5 12.5 C35-49C EL296UH110XV48C 9145144
ML14XC1-048-230 TXV 47000 14.5 12.5 C35-49C EL296UH110XV60C 9145145
ML14XC1-048-230 TXV 47000 15.1 12.5 C35-49C SL280UH090V60C 9145146
ML14XC1-048-230 TXV 47000 15.1 12.5 C35-49C SL280UH090XV60C 9145147
ML14XC1-048-230 TXV 47000 15.1 12.5 C35-49C SL280UH110V60C 9145148
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.