EasyManua.ls Logo

Lennox MERIT ML14XC1 - Page 23

Lennox MERIT ML14XC1
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 23
AHRI SYSTEM MATCHES - ALL REGIONS -041, -047, -048, -059, -060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-048-230 TXV 47000 15 12.5 CBA27UHE-048 10259429
ML14XC1-048-230 TXV 46500 15.1 12.5 CBA27UHE-060 10259430
ML14XC1-048-230 TXV 46500 14.5 12.5 CBX25UH-048 9145198
ML14XC1-048-230 TXV 47000 14.5 12.5 CBX25UHV-048 9145199
ML14XC1-048-230 TXV 46000 14.5 12.5 CBX27UH-048 9145200
ML14XC1-048-230 TXV 47000 15.1 12.5 CBX27UH-060 9145201
ML14XC1-048-230 TXV 46000 14.5 12.2 CBX32M-048 9145202
ML14XC1-048-230 TXV 46500 14.25 12.2 CBX32M-060 9145203
ML14XC1-048-230 TXV 46000 14.5 12.2 CBX32MV-048 9145204
ML14XC1-048-230 TXV 47000 14.5 12.5 CBX32MV-060 9145205
ML14XC1-048-230 TXV 46000 14.5 12.2 CBX40UHV-048 9145206
ML14XC1-048-230 TXV 46500 14.5 12.2 CBX40UHV-060 9145207
ML14XC1-048-230 TXV 44500 14 12.2 CH23-51 EL180UH090E48B 9145208
ML14XC1-048-230 TXV 44000 14.25 12.2 CH23-51 EL180UH110E60C 9145209
ML14XC1-048-230 TXV 44000 14.25 12.2 CH23-51 EL180UH110XE60C 9145210
ML14XC1-048-230 TXV 45000 14.25 12.2 CH23-65 EL180UH090E48B 9145211
ML14XC1-048-230 TXV 45000 14.5 12.2 CH23-65 EL180UH090E60C 9145212
ML14XC1-048-230 TXV 45000 14.25 12.2 CH23-65 EL180UH090XE48B 9145213
ML14XC1-048-230 TXV 45000 14.5 12.5 CH23-65 EL180UH110E60C 9145214
ML14XC1-048-230 TXV 45000 14.5 12.5 CH23-65 EL180UH110XE60C 9145215
ML14XC1-048-230 TXV 47000 15.1 12.5 CH23-68 EL180UH135E60D 9145216
ML14XC1-048-230 TXV 47000 14.5 12.5 CH23-68 EL195UH135XE60D 9145217
ML14XC1-048-230 TXV 47000 14.5 12.5 CH23-68 EL296UH135XE60D 9145218
ML14XC1-048-230 TXV 46500 14 12 CH23-68 9145219
ML14XC1-048-230 TXV 46000 14.5 12.2 CH33-43B EL180UH090E48B 9145221
ML14XC1-048-230 TXV 46000 14.5 12.2 CH33-43B EL180UH090XE48B 9145220
ML14XC1-048-230 TXV 46000 14.5 12.5 CH33-43C EL180UH090E60C 9145222
ML14XC1-048-230 TXV 45500 14.5 12.5 CH33-43C EL180UH110E60C 9145223
ML14XC1-048-230 TXV 45500 14.5 12.5 CH33-43C EL180UH110XE60C 9145224
ML14XC1-048-230 TXV 46000 14.5 12.2 CH33-43C EL195UH090XE48C 9145225
ML14XC1-048-230 TXV 46000 14.5 12.5 CH33-43C EL195UH110XE60C 9145226
ML14XC1-048-230 TXV 46000 14.5 12.2 CH33-43C EL296UH090XE48C 9145227
ML14XC1-048-230 TXV 46000 14.25 12.2 CH33-43C EL296UH090XV48C 9145228
ML14XC1-048-230 TXV 46000 14.25 12.2 CH33-43C EL296UH090XV60C 9145229
ML14XC1-048-230 TXV 46000 14.5 12.5 CH33-43C EL296UH110XE60C 9145230
ML14XC1-048-230 TXV 46000 14.5 12.2 CH33-43C EL296UH110XV48C 9145231
ML14XC1-048-230 TXV 46500 14.25 12.2 CH33-43C EL296UH110XV60C 9145232
ML14XC1-048-230 TXV 46000 14.5 12.5 CH33-43C SL280UH090V60C 9145233
ML14XC1-048-230 TXV 46000 14.5 12.5 CH33-43C SL280UH090XV60C 9145234
ML14XC1-048-230 TXV 46000 14.5 12.2 CH33-43C SL280UH110V60C 9145235
ML14XC1-048-230 TXV 46000 14.5 12.2 CH33-43C SL280UH110XV60C 9145236
ML14XC1-048-230 TXV 46000 14.25 12.2 CH33-43C SLP98UH090XV48C 9145237
ML14XC1-048-230 TXV 46000 14.25 12.2 CH33-43C SLP98UH090XV60C 9145238
ML14XC1-048-230 TXV 46500 14.25 12.2 CH33-43C SLP98UH110XV60C 9145239
ML14XC1-048-230 TXV 45500 14.25 12.2 CH33-44/48B EL180UH090E48B 9145240
ML14XC1-048-230 TXV 45500 14.25 12.2 CH33-44/48B EL180UH090XE48B 9145241
ML14XC1-048-230 TXV 45500 14.5 12.5 CH33-48C EL180UH090E60C 9145242
ML14XC1-048-230 TXV 45500 14.5 12.5 CH33-48C EL180UH110E60C 9145243
ML14XC1-048-230 TXV 45500 14.5 12.5 CH33-48C EL180UH110XE60C 9145244
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Related product manuals