ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 31
AHRI SYSTEM MATCHES - ALL REGIONS -041, -047, -048, -059, -060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-059-230 TXV 56500 15.1 12.5 CH35-51C SL280UH090XV60C 9145746
ML14XC1-059-230 TXV 56500 14.5 12.5 CH35-51C SL280UH110V60C 9145747
ML14XC1-059-230 TXV 56500 14.5 12.5 CH35-51C SL280UH110XV60C 9145748
ML14XC1-059-230 TXV 56500 14.5 12.2 CH35-51C SLP98UH090XV60C 9145750
ML14XC1-059-230 TXV 56000 14.5 12.2 CH35-51C SLP98UH110XV60C 9145749
ML14XC1-059-230 TXV 57000 14.5 12.2 CH35-51C 9145739
ML14XC1-059-230 TXV 57000 15.1 12.5 CH35-60D EL180UH135E60D 9145752
ML14XC1-059-230 TXV 57000 14.5 12.2 CH35-60D EL195UH135XE60D 9145753
ML14XC1-059-230 TXV 57000 14.5 12.2 CH35-60D EL296UH135XE60D 9145755
ML14XC1-059-230 TXV 57000 15.1 12.5 CH35-60D EL296UH135XV60D 9145754
ML14XC1-059-230 TXV 56500 15.5 12.5 CH35-60D SL280UH135V60D 9145756
ML14XC1-059-230 TXV 57000 15.1 12.5 CH35-60D SLP98UH135XV60D 9145757
ML14XC1-059-230 TXV 56500 14.5 12.2 CH35-60D 9145751
ML14XC1-059-230 TXV 55500 14.5 12.2 CR33-50/60 EL180DF110E60C 9145759
ML14XC1-059-230 TXV 55000 14.5 12.2 CR33-50/60 EL195DF110XE60C 9145760
ML14XC1-059-230 TXV 54500 14.25 12 CR33-50/60 EL296DF090XV60C 9145761
ML14XC1-059-230 TXV 55000 14.5 12.2 CR33-50/60 EL296DF110XE60C 9145763
ML14XC1-059-230 TXV 54500 14.25 12 CR33-50/60 EL296DF110XV60C 9145762
ML14XC1-059-230 TXV 55000 14.5 12.2 CR33-50/60 SL280DF090V60C 9145764
ML14XC1-059-230 TXV 55500 14.5 12.2 CR33-50/60 SL280DF110V60C 9145765
ML14XC1-059-230 TXV 54500 14.25 12 CR33-50/60 SLP98DF090XV60C 9145766
ML14XC1-059-230 TXV 54500 14.25 12 CR33-50/60 SLP98DF110XV60C 9145767
ML14XC1-059-230 TXV 55000 14 11.7 CR33-50/60 9145758
ML14XC1-059-230 TXV 55000 14 11.7 CR33-60 9145768
ML14XC1-059-230 TXV 56000 14.5 12.5 CX35-48C EL180UH090E60C 9145822
ML14XC1-059-230 TXV 56000 14.5 12.5 CX35-48C EL180UH110E60C 9145823
ML14XC1-059-230 TXV 56000 14.5 12.5 CX35-48C EL180UH110XE60C 9145824
ML14XC1-059-230 TXV 56000 14.5 12.5 CX35-48C EL195UH110XE60C 9145825
ML14XC1-059-230 TXV 56000 14.5 12.5 CX35-48C EL296UH110XE60C 9145827
ML14XC1-059-230 TXV 55500 14.25 12 CX35-48C EL296UH110XV60C 9145826
ML14XC1-059-230 TXV 55500 14.5 12.2 CX35-48C SL280UH090V60C 9145828
ML14XC1-059-230 TXV 55500 14.5 12.2 CX35-48C SL280UH090XV60C 9145829
ML14XC1-059-230 TXV 55500 14.5 12.2 CX35-48C SL280UH110V60C 9145830
ML14XC1-059-230 TXV 55500 14.5 12.2 CX35-48C SL280UH110XV60C 9145831
ML14XC1-059-230 TXV 55000 14.5 12 CX35-48C SLP98UH090XV60C 9145832
ML14XC1-059-230 TXV 55500 14.25 12 CX35-48C SLP98UH110XV60C 9145833
ML14XC1-059-230 TXV 56000 14.25 12 CX35-48C 9145821
ML14XC1-059-230 TXV 57000 15.1 12.5 CX35-49C EL180UH090E60C 9145835
ML14XC1-059-230 TXV 56500 15.1 12.5 CX35-49C EL180UH110E60C 9145836
ML14XC1-059-230 TXV 56500 15.1 12.5 CX35-49C EL180UH110XE60C 9145837
ML14XC1-059-230 TXV 56500 14.5 12.5 CX35-49C EL195UH110XE60C 9145838
ML14XC1-059-230 TXV 56500 14.5 12.5 CX35-49C EL296UH110XE60C 9145840
ML14XC1-059-230 TXV 57000 14.5 12.5 CX35-49C EL296UH110XV60C 9145839
ML14XC1-059-230 TXV 57000 15.1 12.5 CX35-49C SL280UH090V60C 9145841
ML14XC1-059-230 TXV 57000 15.1 12.5 CX35-49C SL280UH090XV60C 9145842
ML14XC1-059-230 TXV 56500 15.1 12.5 CX35-49C SL280UH110V60C 9145843
ML14XC1-059-230 TXV 56500 15.1 12.5 CX35-49C SL280UH110XV60C 9145844
ML14XC1-059-230 TXV 56000 14.5 12.2 CX35-49C SLP98UH090XV60C 9145845
ML14XC1-059-230 TXV 57000 14.5 12.5 CX35-49C SLP98UH110XV60C 9145846
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.