ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 44
AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S018, S024, S030, S036, S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1S024-230 TXV 24000 16 13 CR33-30/36B EL195DF045XE36B 9148158
ML14XC1S024-230 TXV 24000 16 13 CR33-30/36B EL195DF070XE48B 9148159
ML14XC1S024-230 TXV 24000 16 13 CR33-30/36B EL296DF045XE36B 9148160
ML14XC1S024-230 TXV 24000 16 13 CR33-30/36B EL296DF045XV36B 9148161
ML14XC1S024-230 TXV 24000 16 13 CR33-30/36B EL296DF070XE48B 9148162
ML14XC1S024-230 TXV 24000 16 13 CR33-30/36B EL296DF070XV48B 9148163
ML14XC1S024-230 TXV 24000 16 13 CR33-30/36B SL280DF090V48B 9148164
ML14XC1S024-230 TXV 24000 16 13 CR33-30/36B SLP98DF070XV36B 9148165
ML14XC1S024-230 TXV 24000 14.5 12.2 CR33-30/36B 9148166
ML14XC1S024-230 TXV 24000 16 13 CR33-30/36C SLP98DF090XV36C 9148167
ML14XC1S024-230 TXV 24000 14.5 12.2 CR33-30/36C 9148168
ML14XC1S024-230 TXV 23800 15.1 12.5 CX35-18/24A EL180UH045E36A 9148275
ML14XC1S024-230 TXV 23800 15.1 12.5 CX35-18/24A EL180UH045XE36A 9148276
ML14XC1S024-230 TXV 24000 16 13 CX35-24A EL180UH045E36A 9148277
ML14XC1S024-230 TXV 24000 16 13 CX35-24A EL180UH045XE36A 9148278
ML14XC1S024-230 TXV 24000 16 13 CX35-24A SL280UH070V36A 9148279
ML14XC1S024-230 TXV 24000 16 13 CX35-24A SL280UH070XV36A 9148280
ML14XC1S024-230 TXV 24000 16 13 CX35-24B EL180UH070E36B 9148281
ML14XC1S024-230 TXV 24000 16 13 CX35-24B EL180UH070XE36B 9148282
ML14XC1S024-230 TXV 24000 16 13 CX35-24B EL195UH030XE24B 9148283
ML14XC1S024-230 TXV 24000 16 13 CX35-24B EL195UH045XE24B 9148284
ML14XC1S024-230 TXV 24000 16 13 CX35-24B EL195UH045XE36B 9148285
ML14XC1S024-230 TXV 24000 16 13 CX35-24B EL195UH070XE36B 9148286
ML14XC1S024-230 TXV 24000 16 13 CX35-24B EL296UH045XE36B 9148287
ML14XC1S024-230 TXV 24000 16 13 CX35-24B EL296UH045XV36B 9148288
ML14XC1S024-230 TXV 24000 16 13 CX35-24B EL296UH070XE36B 9148289
ML14XC1S024-230 TXV 24000 16 13 CX35-24B EL296UH070XV36B 9148290
ML14XC1S024-230 TXV 24000 16 13 CX35-24B SL280UH090V36B 9148291
ML14XC1S024-230 TXV 24000 16 13 CX35-24B SL280UH090V48B 9148292
ML14XC1S024-230 TXV 24000 16 13 CX35-24B SL280UH090XV48B 9148293
ML14XC1S024-230 TXV 24000 16 13 CX35-24B SLP98UH070XV36B 9148294
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36A EL180UH045E36A 9148295
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36A EL180UH045XE36A 9148296
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36A SL280UH070V36A 9148297
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36A SL280UH070XV36A 9148298
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B EL180UH070E36B 9148299
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B EL180UH070XE36B 9148300
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B EL195UH030XE24B 9148301
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B EL195UH045XE24B 9148302
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B EL195UH045XE36B 9148303
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B EL195UH070XE36B 9148304
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B EL296UH045XE36B 9148305
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B EL296UH045XV36B 9148306
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B EL296UH070XE36B 9148307
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B EL296UH070XV36B 9148308
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B SL280UH090V36B 9148309
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B SL280UH090V48B 9148310
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B SL280UH090XV48B 9148311
ML14XC1S024-230 TXV 24000 16 13 CX35-30/36B SLP98UH070XV36B 9148312
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.