AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S018, S024, S030, S036, S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1S036-230 TXV 35000 15.5 12.5 C35-36B EL296UH070XE36B 9149216
ML14XC1S036-230 TXV 35000 15.5 12.5 C35-36B EL296UH070XV36B 9149217
ML14XC1S036-230 TXV 35200 16 13 C35-36B SL280UH090V36B 9149218
ML14XC1S036-230 TXV 35200 16 13 C35-36B SL280UH090V48B 9149219
ML14XC1S036-230 TXV 35200 16 13 C35-36B SL280UH090XV48B 9149220
ML14XC1S036-230 TXV 35000 15.5 12.5 C35-36B SLP98UH070XV36B 9149221
ML14XC1S036-230 TXV 34600 14.5 12.2 C35-36B 9149222
ML14XC1S036-230 TXV 35200 16 13 C35-48B EL180UH070E36B 9149223
ML14XC1S036-230 TXV 35200 16 13 C35-48B EL180UH070XE36B 9149224
ML14XC1S036-230 TXV 35600 16 13 C35-48B EL180UH090E48B 9149225
ML14XC1S036-230 TXV 35600 16 13 C35-48B EL180UH090XE48B 9149226
ML14XC1S036-230 TXV 34800 15.5 12.5 C35-48B EL195UH045XE36B 9149227
ML14XC1S036-230 TXV 35200 16 13 C35-48B EL195UH070XE36B 9149228
ML14XC1S036-230 TXV 34800 15.5 12.5 C35-48B EL296UH045XE36B 9149229
ML14XC1S036-230 TXV 35200 15.5 12.5 C35-48B EL296UH045XV36B 9149230
ML14XC1S036-230 TXV 35200 16 13 C35-48B EL296UH070XE36B 9149231
ML14XC1S036-230 TXV 35200 15.5 12.5 C35-48B EL296UH070XV36B 9149232
ML14XC1S036-230 TXV 35400 16 13 C35-48B SL280UH090V36B 9149233
ML14XC1S036-230 TXV 35400 16 13 C35-48B SL280UH090V48B 9149234
ML14XC1S036-230 TXV 35400 16 13 C35-48B SL280UH090XV48B 9149235
ML14XC1S036-230 TXV 35200 15.5 12.5 C35-48B SLP98UH070XV36B 9149236
ML14XC1S036-230 TXV 34800 14.5 12.2 C35-48B 9149237
ML14XC1S036-230 TXV 35600 16 13 C35-48C EL180UH090E60C 9149238
ML14XC1S036-230 TXV 35200 16 13 C35-48C EL180UH110E60C 9149239
ML14XC1S036-230 TXV 35200 16 13 C35-48C EL180UH110XE60C 9149240
ML14XC1S036-230 TXV 35400 16 13 C35-48C EL195UH090XE48C 9149241
ML14XC1S036-230 TXV 35600 16 13 C35-48C EL195UH110XE60C 9149242
ML14XC1S036-230 TXV 35400 16 13 C35-48C EL296UH090XE48C 9149243
ML14XC1S036-230 TXV 35400 16 13 C35-48C EL296UH090XV36C 9149244
ML14XC1S036-230 TXV 35200 16 13 C35-48C EL296UH090XV48C 9149245
ML14XC1S036-230 TXV 35600 16 13 C35-48C EL296UH110XE60C 9149246
ML14XC1S036-230 TXV 35400 16 13 C35-48C EL296UH110XV48C 9149247
ML14XC1S036-230 TXV 35800 16 13 C35-48C EL296UH110XV60C 9149248
ML14XC1S036-230 TXV 35800 16 13 C35-48C SL280UH090V60C 9149249
ML14XC1S036-230 TXV 35800 16 13 C35-48C SL280UH090XV60C 9149250
ML14XC1S036-230 TXV 35800 16 13 C35-48C SL280UH110V60C 9149251
ML14XC1S036-230 TXV 35800 16 13 C35-48C SL280UH110XV60C 9149252
ML14XC1S036-230 TXV 35400 16 13 C35-48C SLP98UH090XV36C 9149253
ML14XC1S036-230 TXV 35200 16 13 C35-48C SLP98UH090XV48C 9149254
ML14XC1S036-230 TXV 35800 16 13 C35-48C SLP98UH110XV60C 9149255
ML14XC1S036-230 TXV 34800 14.5 12.2 C35-48C 9149256
ML14XC1S036-230 TXV 36000 16 13 C35-49C EL180UH090E60C 9149257
ML14XC1S036-230 TXV 35600 16 13 C35-49C EL180UH110E60C 9149258
ML14XC1S036-230 TXV 35600 16 13 C35-49C EL180UH110XE60C 9149259
ML14XC1S036-230 TXV 35600 16 13 C35-49C EL195UH090XE48C 9149260
ML14XC1S036-230 TXV 36000 16 13 C35-49C EL195UH110XE60C 9149261
ML14XC1S036-230 TXV 35600 16 13 C35-49C EL296UH090XE48C 9149262
ML14XC1S036-230 TXV 35800 16 13 C35-49C EL296UH090XV36C 9149263
ML14XC1S036-230 TXV 35600 16 13 C35-49C EL296UH090XV48C 9149264
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.