ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 59
AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S018, S024, S030, S036, S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1S036-230 TXV 34200 16 13 CH33-42B EL180UH070XE36B 9149411
ML14XC1S036-230 TXV 34400 15.5 12.5 CH33-42B EL180UH090E48B 9149412
ML14XC1S036-230 TXV 34400 15.5 12.5 CH33-42B EL180UH090XE48B 9149413
ML14XC1S036-230 TXV 34200 14.5 12.2 CH33-42B EL195UH045XE36B 9149414
ML14XC1S036-230 TXV 34000 15.1 12.5 CH33-42B EL195UH070XE36B 9149415
ML14XC1S036-230 TXV 34200 14.5 12.2 CH33-42B EL296UH045XE36B 9149416
ML14XC1S036-230 TXV 34400 15.1 12.5 CH33-42B EL296UH045XV36B 9149417
ML14XC1S036-230 TXV 34000 15.1 12.5 CH33-42B EL296UH070XE36B 9149418
ML14XC1S036-230 TXV 34400 15.1 12.5 CH33-42B EL296UH070XV36B 9149419
ML14XC1S036-230 TXV 34600 16 13 CH33-42B SL280UH090V36B 9149420
ML14XC1S036-230 TXV 34600 15.5 12.5 CH33-42B SL280UH090V48B 9149421
ML14XC1S036-230 TXV 34600 15.5 12.5 CH33-42B SL280UH090XV48B 9149422
ML14XC1S036-230 TXV 34400 15.1 12.5 CH33-42B SLP98UH070XV36B 9149423
ML14XC1S036-230 TXV 35600 16 13 CH33-43B EL180UH070E36B 9149424
ML14XC1S036-230 TXV 35600 16 13 CH33-43B EL180UH070XE36B 9149425
ML14XC1S036-230 TXV 35800 16 13 CH33-43B EL180UH090E48B 9149426
ML14XC1S036-230 TXV 35800 16 13 CH33-43B EL180UH090XE48B 9149427
ML14XC1S036-230 TXV 35600 15.5 12.5 CH33-43B EL195UH045XE36B 9149428
ML14XC1S036-230 TXV 35400 16 13 CH33-43B EL195UH070XE36B 9149429
ML14XC1S036-230 TXV 35600 15.5 12.5 CH33-43B EL296UH045XE36B 9149430
ML14XC1S036-230 TXV 35800 16 13 CH33-43B EL296UH045XV36B 9149431
ML14XC1S036-230 TXV 35400 16 13 CH33-43B EL296UH070XE36B 9149432
ML14XC1S036-230 TXV 35800 16 13 CH33-43B EL296UH070XV36B 9149433
ML14XC1S036-230 TXV 36000 16 13 CH33-43B SL280UH090V36B 9149434
ML14XC1S036-230 TXV 36000 16 13 CH33-43B SL280UH090V48B 9149435
ML14XC1S036-230 TXV 36000 16 13 CH33-43B SL280UH090XV48B 9149436
ML14XC1S036-230 TXV 35800 16 13 CH33-43B SLP98UH070XV36B 9149437
ML14XC1S036-230 TXV 35400 15.1 12.5 CH33-43B 9149439
ML14XC1S036-230 TXV 35600 16 13 CH33-43C EL180UH090E60C 9149440
ML14XC1S036-230 TXV 35400 16 13 CH33-43C EL180UH110E60C 9149441
ML14XC1S036-230 TXV 35400 16 13 CH33-43C EL180UH110XE60C 9149442
ML14XC1S036-230 TXV 35400 16 13 CH33-43C EL195UH090XE48C 9149443
ML14XC1S036-230 TXV 35600 16 13 CH33-43C EL195UH110XE60C 9149444
ML14XC1S036-230 TXV 35400 16 13 CH33-43C EL296UH090XE48C 9149445
ML14XC1S036-230 TXV 35400 16 13 CH33-43C EL296UH090XV36C 9149446
ML14XC1S036-230 TXV 35200 16 13 CH33-43C EL296UH090XV48C 9149447
ML14XC1S036-230 TXV 35600 16 13 CH33-43C EL296UH110XE60C 9149448
ML14XC1S036-230 TXV 35400 16 13 CH33-43C EL296UH110XV48C 9149449
ML14XC1S036-230 TXV 35800 16 13 CH33-43C EL296UH110XV60C 9149450
ML14XC1S036-230 TXV 35800 16 13 CH33-43C SL280UH090V60C 9149451
ML14XC1S036-230 TXV 35800 16 13 CH33-43C SL280UH090XV60C 9149452
ML14XC1S036-230 TXV 35600 16 13 CH33-43C SL280UH110V60C 9149453
ML14XC1S036-230 TXV 35600 16 13 CH33-43C SL280UH110XV60C 9149454
ML14XC1S036-230 TXV 35400 16 13 CH33-43C SLP98UH090XV36C 9149455
ML14XC1S036-230 TXV 35200 16 13 CH33-43C SLP98UH090XV48C 9149456
ML14XC1S036-230 TXV 35800 16 13 CH33-43C SLP98UH110XV60C 9149457
ML14XC1S036-230 TXV 34600 16 13 CH33-44/48B EL180UH070E36B 9149458
ML14XC1S036-230 TXV 34600 16 13 CH33-44/48B EL180UH070XE36B 9149459
ML14XC1S036-230 TXV 35000 16 13 CH33-44/48B EL180UH090E48B 9149460
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.