ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 75
AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S018, S024, S030, S036, S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1S042-230 TXV 41000 15.5 12.5 CX35-36B SL280UH090V36B 9147451
ML14XC1S042-230 TXV 41000 15.5 12.5 CX35-36B SL280UH090V48B 9147452
ML14XC1S042-230 TXV 41000 15.5 12.5 CX35-36B SL280UH090XV48B 9147453
ML14XC1S042-230 TXV 41000 15.1 12.5 CX35-36B SLP98UH070XV36B 9147454
ML14XC1S042-230 TXV 41000 14.5 12.2 CX35-36B 9147455
ML14XC1S042-230 TXV 41500 16 13 CX35-48B EL180UH090E48B 9147456
ML14XC1S042-230 TXV 41500 16 13 CX35-48B EL180UH090XE48B 9147457
ML14XC1S042-230 TXV 41000 15.1 12.5 CX35-48B EL296UH045XV36B 9147458
ML14XC1S042-230 TXV 41000 15.1 12.5 CX35-48B EL296UH070XV36B 9147459
ML14XC1S042-230 TXV 41500 15.5 12.5 CX35-48B SL280UH090V36B 9147460
ML14XC1S042-230 TXV 41500 15.5 12.5 CX35-48B SL280UH090V48B 9147461
ML14XC1S042-230 TXV 41500 15.5 12.5 CX35-48B SL280UH090XV48B 9147462
ML14XC1S042-230 TXV 41000 15.1 12.5 CX35-48B SLP98UH070XV36B 9147463
ML14XC1S042-230 TXV 41000 14.5 12.2 CX35-48B 9147464
ML14XC1S042-230 TXV 41500 16 13 CX35-48C EL180UH090E60C 9147465
ML14XC1S042-230 TXV 41500 16 13 CX35-48C EL180UH110E60C 9147466
ML14XC1S042-230 TXV 41500 16 13 CX35-48C EL180UH110XE60C 9147467
ML14XC1S042-230 TXV 41500 16 13 CX35-48C EL195UH090XE48C 9147468
ML14XC1S042-230 TXV 41500 16 13 CX35-48C EL195UH110XE60C 9147469
ML14XC1S042-230 TXV 41500 16 13 CX35-48C EL296UH090XE48C 9147470
ML14XC1S042-230 TXV 41500 15.5 13 CX35-48C EL296UH090XV36C 9147471
ML14XC1S042-230 TXV 41500 16 13 CX35-48C EL296UH090XV48C 9147472
ML14XC1S042-230 TXV 41500 15.5 13 CX35-48C EL296UH090XV60C 9147473
ML14XC1S042-230 TXV 41500 16 13 CX35-48C EL296UH110XE60C 9147474
ML14XC1S042-230 TXV 41500 16 13 CX35-48C EL296UH110XV48C 9147475
ML14XC1S042-230 TXV 41500 16 13 CX35-48C EL296UH110XV60C 9147476
ML14XC1S042-230 TXV 42000 16 13 CX35-48C SL280UH090V60C 9147477
ML14XC1S042-230 TXV 42000 16 13 CX35-48C SL280UH090XV60C 9147478
ML14XC1S042-230 TXV 41500 16 13 CX35-48C SL280UH110V60C 9147479
ML14XC1S042-230 TXV 41500 16 13 CX35-48C SL280UH110XV60C 9147480
ML14XC1S042-230 TXV 41500 15.5 13 CX35-48C SLP98UH090XV36C 9147481
ML14XC1S042-230 TXV 41500 16 13 CX35-48C SLP98UH090XV48C 9147482
ML14XC1S042-230 TXV 41500 15.5 13 CX35-48C SLP98UH090XV60C 9147483
ML14XC1S042-230 TXV 41500 16 13 CX35-48C SLP98UH110XV60C 9147484
ML14XC1S042-230 TXV 41000 14.5 12.2 CX35-48C 9147485
ML14XC1S042-230 TXV 42000 16 13 CX35-49C EL180UH090E60C 9147486
ML14XC1S042-230 TXV 42000 16 13 CX35-49C EL180UH110E60C 9147487
ML14XC1S042-230 TXV 42000 16 13 CX35-49C EL180UH110XE60C 9147488
ML14XC1S042-230 TXV 41500 16 13 CX35-49C EL195UH090XE48C 9147489
ML14XC1S042-230 TXV 42000 16 13 CX35-49C EL195UH110XE60C 9147490
ML14XC1S042-230 TXV 41500 16 13 CX35-49C EL296UH090XE48C 9147491
ML14XC1S042-230 TXV 41500 16 13 CX35-49C EL296UH090XV36C 9147492
ML14XC1S042-230 TXV 41500 16 13 CX35-49C EL296UH090XV48C 9147493
ML14XC1S042-230 TXV 42000 16 13 CX35-49C EL296UH090XV60C 9147494
ML14XC1S042-230 TXV 42000 16 13 CX35-49C EL296UH110XE60C 9147495
ML14XC1S042-230 TXV 42000 16 13 CX35-49C EL296UH110XV48C 9147496
ML14XC1S042-230 TXV 42000 16 13 CX35-49C EL296UH110XV60C 9147497
ML14XC1S042-230 TXV 42000 16 13 CX35-49C SL280UH090V60C 9147498
ML14XC1S042-230 TXV 42000 16 13 CX35-49C SL280UH090XV60C 9147499
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.