ML14XC1 - 1.5 to 5 Ton Air Conditioner / Page 91
AHRI SYSTEM MATCHES - SOUTHWEST REGIONS -018, -024, -030, 036, -042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
ML14XC1-030-230 TXV 29400 16 13 CH33-31B EL180UH070XE36B 9142337
ML14XC1-030-230 TXV 29400 16 13 CH33-31B EL180UH090E48B 9142338
ML14XC1-030-230 TXV 29400 16 13 CH33-31B EL180UH090XE48B 9142339
ML14XC1-030-230 TXV 29200 15.5 13 CH33-31B EL195UH045XE36B 9142340
ML14XC1-030-230 TXV 29400 15.5 13 CH33-31B EL195UH070XE36B 9142341
ML14XC1-030-230 TXV 29200 15.5 13 CH33-31B EL296UH045XE36B 9142342
ML14XC1-030-230 TXV 29200 15.5 13 CH33-31B EL296UH045XV36B 9142343
ML14XC1-030-230 TXV 29400 15.5 13 CH33-31B EL296UH070XE36B 9142344
ML14XC1-030-230 TXV 29200 16 13 CH33-31B EL296UH070XV36B 9142345
ML14XC1-030-230 TXV 29200 16 13 CH33-31B SL280UH090V36B 9142346
ML14XC1-030-230 TXV 29200 16 13 CH33-31B SLP98UH070XV36B 9142347
ML14XC1-030-230 TXV 28800 14.5 12.2 CH33-31B 9142349
ML14XC1-030-230 TXV 28200 15.1 12.5 CH33-36A EL180UH045E36A 9142350
ML14XC1-030-230 TXV 28200 15.1 12.5 CH33-36A EL180UH045XE36A 9142351
ML14XC1-030-230 TXV 28200 15.1 12.5 CH33-36A SL280UH070V36A 9142352
ML14XC1-030-230 TXV 28200 15.1 12.5 CH33-36A SL280UH070XV36A 9142353
ML14XC1-030-230 TXV 28400 15.5 12.5 CH33-36B EL180UH070E36B 9142354
ML14XC1-030-230 TXV 28400 15.5 12.5 CH33-36B EL180UH070XE36B 9142355
ML14XC1-030-230 TXV 28400 15.5 13 CH33-36B EL180UH090E48B 9142356
ML14XC1-030-230 TXV 28400 15.5 13 CH33-36B EL180UH090XE48B 9142357
ML14XC1-030-230 TXV 28400 15.1 12.5 CH33-36B EL195UH045XE36B 9142358
ML14XC1-030-230 TXV 28400 15.1 12.5 CH33-36B EL195UH070XE36B 9142359
ML14XC1-030-230 TXV 28400 15.1 12.5 CH33-36B EL296UH045XE36B 9142360
ML14XC1-030-230 TXV 28400 15.1 12.5 CH33-36B EL296UH045XV36B 9142361
ML14XC1-030-230 TXV 28400 15.1 12.5 CH33-36B EL296UH070XE36B 9142362
ML14XC1-030-230 TXV 28400 15.5 12.5 CH33-36B SL280UH090V36B 9142363
ML14XC1-030-230 TXV 28400 15.5 12.5 CH33-36B SLP98UH070XV36B 9142364
ML14XC1-030-230 TXV 28600 16 13 CH33-36C EL195UH090XE48C 9142365
ML14XC1-030-230 TXV 28600 16 13 CH33-36C EL296UH090XE48C 9142366
ML14XC1-030-230 TXV 28600 16 13 CH33-36C EL296UH090XV36C 9142367
ML14XC1-030-230 TXV 28600 16 13 CH33-36C SLP98UH090XV36C 9142368
ML14XC1-030-230 TXV 29200 16 13 CH33-42 EL180UH070E36B 9142369
ML14XC1-030-230 TXV 29200 16 13 CH33-42 EL180UH070XE36B 9142370
ML14XC1-030-230 TXV 29200 16 13 CH33-42 EL180UH090E48B 9142371
ML14XC1-030-230 TXV 29200 16 13 CH33-42 EL180UH090XE48B 9142372
ML14XC1-030-230 TXV 29000 15.5 12.5 CH33-42 EL195UH045XE36B 9142373
ML14XC1-030-230 TXV 29200 15.5 12.5 CH33-42 EL195UH070XE36B 9142374
ML14XC1-030-230 TXV 29000 15.5 12.5 CH33-42 EL296UH045XE36B 9142375
ML14XC1-030-230 TXV 29000 15.5 12.5 CH33-42 EL296UH045XV36B 9142376
ML14XC1-030-230 TXV 29200 15.5 12.5 CH33-42 EL296UH070XE36B 9142377
ML14XC1-030-230 TXV 29000 15.5 13 CH33-42 EL296UH070XV36B 9142378
ML14XC1-030-230 TXV 29000 15.5 13 CH33-42 SLP98UH070XV36B 9142379
ML14XC1-030-230 TXV 29600 16 13 CH33-43B EL180UH070E36B 9142380
ML14XC1-030-230 TXV 29600 16 13 CH33-43B EL180UH070XE36B 9142381
ML14XC1-030-230 TXV 29600 16 13 CH33-43B EL180UH090E48B 9142382
ML14XC1-030-230 TXV 29600 16 13 CH33-43B EL180UH090XE48B 9142383
ML14XC1-030-230 TXV 29400 16 13 CH33-43B EL195UH045XE36B 9142384
ML14XC1-030-230 TXV 29600 16 13 CH33-43B EL195UH070XE36B 9142385
ML14XC1-030-230 TXV 29400 16 13 CH33-43B EL296UH045XE36B 9142386
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certied to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for eld installation. See furnace or air handler specications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

Related product manuals