MINI-SPLIT SYSTEMS SERVICE MANUAL
CORP1602-L9
3/2017
Supersedes 10/2016
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss
of life.
Installation and service must be performed by a licensed professional HVAC installer (or equivalent) or service agency

Table of Contents

Other manuals for Lennox MMDA048S4-*P

Questions and Answers

  • K
    Kevin HunterAug 13, 2025
    What to do if my Lennox Air Conditioner shows an outdoor EEPROM malfunction?
    • B
      bakersharonAug 13, 2025
      If your Lennox Air Conditioner displays an outdoor EEPROM malfunction, try these steps: * Power off the unit, then restart it after 3 minutes. * If the issue persists, the outdoor main PCB may need to be replaced.
  • J
    Jennifer MartinAug 17, 2025
    What to do if my Lennox Air Conditioner shows a communication error E2?
    • E
      eacostaAug 17, 2025
      If your Lennox Air Conditioner is showing a communication error (E2 for outdoor code) between the indoor and outdoor units, the first step is to check the wiring and connections between these units to ensure they are secure and properly connected.
  • C
    Connie Weeks MDAug 21, 2025
    What to do if my Lennox Air Conditioner has low refrigerant?
    • H
      hendersonrandyAug 21, 2025
      If your Lennox Air Conditioner is experiencing a low refrigerant issue, contact a qualified technician to check for leaks.
  • D
    David JohnsonAug 25, 2025
    What to do if my Lennox Air Conditioner has an outdoor coil temperature sensor error (T3)?
    • R
      Robin MorrisAug 25, 2025
      If your Lennox Air Conditioner's outdoor coil temperature sensor (T3) is showing an error, check the sensor connections and condition.
  • R
    Roy WillisAug 28, 2025
    How to fix a Lennox Air Conditioner compressor discharge temperature sensor error (T5)?
    • B
      Benjamin JamesAug 28, 2025
      If your Lennox Air Conditioner's compressor discharge temperature sensor (T5) is showing an error, examine the sensor and its wiring.
  • J
    John FreySep 1, 2025
    How to troubleshoot an indoor fan speed error on my Lennox MMDA048S4-*P?
    • S
      Stephanie AdamsSep 2, 2025
      If the Lennox Air Conditioner displays an indoor fan speed error, inspect the fan motor and connections.
  • J
    Jocelyn McintoshSep 5, 2025
    What to do if my Lennox MMDA048S4-*P Air Conditioner shows an indoor coil temperature sensor error?
    • J
      Johnny RobinsonSep 5, 2025
      If your Lennox Air Conditioner has an indoor coil temperature sensor error, inspect the sensor for damage.
  • S
    Shirley GarciaSep 9, 2025
    How do I fix an indoor return air temperature sensor error on my Lennox MMDA048S4-*P Air Conditioner?
    • J
      Jennifer NewmanSep 9, 2025
      If your Lennox Air Conditioner has an indoor return air temperature sensor error, check the sensor and its wiring.

Summary

General Safety Warning

Chapter 1: Single and Multiple Zone Outdoor Units

MPA Single-Zone Outdoor Unit Specs (0.75-1.5 Ton)

Details technical specifications for MPA single-zone outdoor units from 0.75 to 1.5 tons.

MPA Multi-Zone Outdoor Unit Specs (1.5-2.5 Ton)

Details technical specifications for MPA multi-zone outdoor units from 1.5 to 2.5 tons.

Chapter 2: M22 A, M33 A and M33 B Cassette Non-Ducted Indoor Units

Chapter 3: MMDA Ducted Indoor Units

MMDA Indoor Unit Specifications

Lists key technical specifications for MMDA indoor units.

Chapter 4: MWMA and MWMB Wall Mounted Indoor Units

Chapter 5: MCFA and MCFB Ceiling; Floor Indoor Units

Chapter 6: Indoor; Outdoor Unit Combinations

MPA Multi-Zone System Combinations

Lists valid indoor/outdoor unit combinations for MPA multi-zone systems.

Chapter 7: Refrigeration Pipe Work

Chapter 9: MPA, MPB and MLA Outdoor Unit Connections and Line Set Usage

Chapter 10: Power Wiring for Outdoor and Indoor Units

Chapter 11: Outdoor Unit Diagrams

Chapter 12: Indoor Unit Diagrams

Chapter 14: Condensate Pipe Work Installation

Chapter 15: Controls

Chapter 16: Connection to Centralized Controller

Chapter 19: Start-Up Procedures

Adding Refrigerant for Single-Zone Systems

Procedures for adding refrigerant to single-zone systems.

Adding Refrigerant for Multi-Zone Systems

Procedures for adding refrigerant to multi-zone systems.

Chapter 20: Quick Reference Guide - Error Codes

Chapter 23: Troubleshooting Outdoor Unit Error Codes

Chapter 24: Indoor Unit Indicators and Controls

Chapter 25: Troubleshooting Indoor Unit Error Codes

Component Troubleshooting Procedures

Compressor Resistance Check

Procedure to measure compressor winding resistance.

IPM Check

Procedure to measure IPM resistance values.

AC Fan Motor Resistance Check

Procedure to measure AC fan motor winding resistance.

Four-Way Valve Testing Procedure

Steps to test the four-way valve voltage and resistance.

EXV Connector Pin-Out and Resistance

Details EXV connector pin-out and resistance measurement.

Component Protection Functions

System Specifications and Operations

Capacity Request Calculations

Explains how to calculate system capacity based on indoor/outdoor conditions.

Defrost Control Logic

Details the conditions and logic for initiating and terminating defrost mode.

Outdoor Fan Speed Control Logic

Explains how outdoor fan speed is selected based on ambient temperature.

EXV Control Logic

Describes the operation and control logic of the Electronic Expansion Valve.

Lennox MMDA048S4-*P Specifications

General IconGeneral
BrandLennox
ModelMMDA048S4-*P
CategoryAir Conditioner
LanguageEnglish

Related product manuals