INSTALLATION
INSTRUCTIONS
©
2017 Lennox Industries Inc.
Dallas, Texas, USA
WARNING
Improper installation, adjustment, alteration, ser vice or
maintenance can cause property damage, personal
injury or loss of life.
Installation and service must be performed by a li censed
professional HVAC installer (or equivalent) or a service
agency.
WARNING
The clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs, and HFCs) as of July, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for non-compliance.
WARNING
This product contains a chemical known to the State
of California to cause cancer, birth defects, or other
reproductive harm.
CAUTION
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
General
These instructions are intended as a general guide and
do not supersede local or national codes in any way.
Authorities having jurisdiction should be consulted before
installation.
The MWMA and MWMB wall-mounted indoor units are
matched with an outdoor heat pump unit to create a mini-
split system that uses HFC-410A refrigerant.
MLA/MPA/MPB and
MWMA/MWMB Series
SINGLE-ZONE MINI-SPLIT SYSTEMS
(115V and 208/230V) --
Wall-Mounted Indoor Unit
507545-06
4/2017
Supersedes 10/2016
Table of Contents
General ...........................................................................1
Included Parts.................................................................2
Model Number Identication ...........................................3
Indoor / Outdoor Unit Match-Ups....................................4
Typical System Components ..........................................5
System Dimensions ........................................................6
Outdoor Units ..............................................................6
Indoor Units .................................................................7
System Clearances ........................................................8
Outdoor Unit ................................................................8
Indoor Unit ...................................................................8
Torque Requirements for Caps and Fasteners...............9
Indoor Unit Installation ....................................................9
Unit Placement Considerations ...................................9
Determining Wall Mounting Plate Location ..................9
Installation of Wall Mounting Plate...............................9
Installation of Wall Sleeve..........................................10
Installation of Indoor Unit on Wall Mounting Plate .....10
Indoor Unit Condensate Piping Connections .............12
Outdoor Unit Installation ...............................................12
Placement Considerations .........................................12
Direct Sunlight, Rain, Snow and Ice Protection .........13
Prevailing Winds ........................................................14
Buried Refrigerant Pipe Protection ............................14
Outdoor Unit Condensate Piping ...............................14
Securing the Outdoor Unit .........................................15
Refrigerant Piping Connections ....................................15
Leak Test and Evacuation ............................................18
Leak Test ...................................................................18
Triple Evacuation Procedure......................................18
Wiring Connections ......................................................18
Outdoor Unit .............................................................18
Indoor Unit .................................................................18
Unit Start-Up .................................................................26
Adding Refrigerant for Longer Line Set ........................26
Troubleshooting ............................................................26
Test Run .......................................................................26
Pre-Checks ................................................................26
Procedure ..................................................................26
Double-Check Pipe Connections ...............................27
If Ambient Temperature is below 63°F (17°C) ...........27
Dry Mode Operation (Dehumidication) .......................27
Procedure ..................................................................27
Sequence of Operation ..............................................27
THIS MANUAL MUST BE LEFT WITH THE OWNER
FOR FUTURE REFERENCE

Questions and Answers

  • E
    Emily LaneSep 15, 2025
    How to fix compressor drive error in Lennox Air Conditioner?
    • J
      Jason GomezSep 15, 2025
      To fix a compressor drive error in your Lennox Air Conditioner, inspect the compressor and associated drive components.
  • D
    Dawn JohnsonAug 25, 2025
    What to do if my Lennox Air Conditioner has a communication error between the indoor and outdoor unit?
    • T
      Tyler BrewerAug 25, 2025
      If your Lennox Air Conditioner displays a communication error between the indoor and outdoor units, check the wiring and connections between these units to ensure they are properly connected.
  • S
    Sheri SanchezAug 26, 2025
    What to do if my Lennox MPA009S4S-*P is experiencing high or low voltage protection?
    • B
      Brad SandovalAug 26, 2025
      If your Lennox Air Conditioner is experiencing high or low voltage protection, check the power supply and ensure voltage levels are within the proper specifications.
  • H
    hpachecoAug 26, 2025
    What to do if my Lennox MPA009S4S-*P Air Conditioner's outdoor unit senses a current overload?
    • J
      Julie FrancisAug 27, 2025
      If your Lennox Air Conditioner's outdoor unit senses a current overload, inspect the electrical connections and the compressor for any issues.
  • K
    Katherine WoodsSep 16, 2025
    What to do for compressor pressure switch issues in Lennox MPA009S4S-*P?
    • P
      Patrick CampbellSep 16, 2025
      If your Lennox Air Conditioner has a compressor high-pressure or low-pressure switch open, investigate system pressures and correct abnormalities.
  • J
    jorgebrandtSep 23, 2025
    What to do if my Lennox MPA009S4S-*P has an outdoor coil temperature sensor error?
    • R
      Ricky MitchellSep 23, 2025
      If your Lennox Air Conditioner shows an outdoor coil temperature sensor error, inspect and verify the sensor's condition.
  • L
    Luis WeissSep 8, 2025
    How to fix a Lennox MPA009S4S-*P compressor discharge temperature sensor error (T5)?
    • B
      Benjamin UnderwoodSep 8, 2025
      If your Lennox Air Conditioner's compressor discharge temperature sensor (T5) is showing an error, examine the sensor and its wiring.
  • D
    Daniel WolfSep 8, 2025
    How to troubleshoot an indoor fan speed error on my Lennox Air Conditioner?
    • J
      James PaulSep 9, 2025
      If the Lennox Air Conditioner displays an indoor fan speed error, inspect the fan motor and connections.
  • A
    Albert PhelpsSep 2, 2025
    What to do if my Lennox Air Conditioner displays a compressor discharge temperature sensor error?
    • A
      Ashley SpencerSep 2, 2025
      If your Lennox Air Conditioner displays a compressor discharge temperature sensor error, replace the compressor discharge temperature sensor.
  • D
    David VelezAug 31, 2025
    What to do if my Lennox Air Conditioner displays an indoor coil temperature sensor error?
    • K
      keithbrownAug 31, 2025
      If your Lennox Air Conditioner displays an indoor coil temperature sensor error, check the indoor coil temperature sensor and replace it if necessary.