SPECIFICATIONS BELT DRIVE MODELS - 6 TON
General Data Nominal Tonnage 6 Ton 6 Ton
Model No. ZGB074S4B ZGB074S4T
󰀩 Standard Standard
Blower Type Single Speed
Belt Drive
Two Speed
Belt Drive
Cooling
Performance
Gross Cooling Capacity - Btuh  
1
Net Cooling Capacity - Btuh  
  
2
  
  
1
 12.7 
1
  
Refrigerant Type  
Charge Furnished 7 lbs. 3 oz. 7 lbs. 3 oz.
Gas Heating Options - See page 15 Standard (1 stage),
Medium (1 or 2 stage) or
High (1 or 2 stage)
Standard (1 stage),
Medium (1 or 2 stage) or
High (1 or 2 stage)
Compressor Type (one per unit) Two-Stage Scroll Two-Stage Scroll
Outdoor Coil Net face area - sq. ft.  
Number of rows 1 1
Fins / inch 23 23
Outdoor
Coil Fan
Motor HP  
Motor rpm  
Total motor watts  
  
Number of blades 3 3
Total air volume - cfm  
Indoor Coil Net face area - sq. ft.  
Tube diameter - in.  
Number of rows 3 3
Fins per inch  
  
Expansion device type  
3
Indoor
Blower & Drive
Selection
Nominal Motor HP  2 hp
Maximum Usable Motor HP  2.3 hp
Available Drive Kits 











  
Filters Type Disposable Disposable
Number and size - in. 



Electrical Characteristics - 60 Hz 

575V - 3ph


575V - 3ph
NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction.
1

2

3
Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor hp required. Maximum usable hp of motors

factor limitations outlined on the motor nameplate.