4. Align the tabs on the sides of the air baffle with the slots on the power-supply
cage.
5. Place your fingers into the handle 4 and finger hole on the top of the DIMM
air baffle.
6. Press the handle 4 toward the finger hole and lower the air baffle so that the
lip on the right side of the baffle covers the lip on the side of the power-supply
cage.
7. Press the DIMM air baffle into place.
Attention: For proper cooling and airflow, replace the air baffle before you turn on
the server. Operating the server with an air baffle removed might damage server
components.
Installing an adapter
1 Expansion slot covers 5 Low profile PCI Express adapter
2 Riser-card assembly 6 Expansion slot cover
3 Expansion slot 1 7 Expansion slot 2
4 Adapter 8 Adapter
Chapter 2. Installing optional devices 39