Table 63. LCD display panel messages (continued)
Message Description
Amount of time before
the system timeout if no
activity
Action
IMM: LOADING
IMM is loading the
kernel.
After 15 minutes of no
activity or 10 IMM reboot
cycles
1. Disconnect the
power from the
server.
2. Perform a web or
inband flash of the
IMM firmware using
TFTP burn.
IMM: SECURE BOOT
IMM is loading the
kernel.
After 15 minutes of no
activity or 10 IMM reboot
cycles
1. Disconnect the
power from the
server.
2. Reset IMM, see
“Setup utility menu
choices” on page
123.
3. Replace the
standard I/O book.
IMM: KERNEL BOOT
IMM is loading the
kernel.
After 15 minutes of no
activity or 10 IMM reboot
cycles
1. Disconnect the
power from the
server.
2. Reset IMM, see
“Setup utility menu
choices” on page
123.
3. Replace the
standard I/O book.
IMM: NETWORK IMM is loading the
kernel.
After 15 minutes of no
activity or 10 IMM reboot
cycles
1. Disconnect the
power from the
server.
2. Perform a web or
inband flash of the
IMM firmware using
TFTP burn.
IMM: BOOTING
IMM is loading the
kernel.
After 15 minutes of no
activity or 10 IMM reboot
cycles
1. Disconnect the
power from the
server.
2. Perform a web or
inband flash of the
IMM firmware using
TFTP burn.
IMM: PWR ACTIONS
IMM is loading the
kernel.
After 15 minutes of no
activity or 10 IMM reboot
cycles
1. Disconnect the
power from the
server.
2. Perform a web or
inband flash of the
IMM firmware using
TFTP burn.
342 System x3850 X6 and x3950 X6 Installation and Service Guide