Table 63. LCD display panel messages (continued)
Message Description
Amount of time before
the system timeout if no
activity
Action
UEFI: DXE INIT DXE is running. After 2 minutes
1. Restart the server.
2. Flash the UEFI
firmware.
3. Clear CMOS.
UEFI: PECI INIT The PECI data is
ready to be read by
IMM.
After 2 minutes
1. Restart the server.
2. Flash the UEFI
firmware.
3. Clear CMOS.
UEFI: USB INIT The USB bus is
being initialized.
After 2 minutes
1. Inspect the USB
subsystem.
2. Restart the server.
UEFI: PCI INIT PCIe initialization is
running.
After 10 minutes Inspect the PCIe
subsystem.
UEFI: VIDEO INIT Video initialization is
running.
After 2 minutes
1. Restart the server.
2. Flash the UEFI
firmware.
3. Clear CMOS.
UEFI: SMBIOS RDY The SMBIOS tables
are ready to be sent
to IMM.
After 2 minutes
1. Restart the server.
2. Flash the UEFI
firmware.
3. Clear CMOS.
UEFI: SMI INS
UEFI is running. After 2 minutes
1. Restart the server.
2. Flash the UEFI
firmware.
3. Clear CMOS.
UEFI: BOOTLEG Booting legacy. After 2 minutes Make sure that the boot
operating system is
installed correctly.
UEFI: UNMAP DSA UEFI is running. After 2 minutes
1. Restart the server.
2. Flash the UEFI
firmware.
3. Clear CMOS.
IMM: UBOOT
IMM is loading
UBOOT.
After 15 minutes of no
activity or 10 IMM reboot
cycles
1. Disconnect the
power from the
server.
2. Reset IMM, see
“Setup utility menu
choices” on page
123.
3. Replace the
standard I/O book.
Appendix A. LCD display panel messages 341