ErrorcodePOSTErrorMessageDescription/Action
0135
Fanfailure
Thesystemmightbeoverheating.
PressF10toexit.
Note:Iftheproblemiscausedbythe
microprocessorfan,pressF10will
notsolvetheproblem.
0211
Keyboardnotfound
Whenthereisnokeyboarddetected,
theerrormessagewillbedisplayed.
0164MemorysizedecreasedPressF10toexit.
1762
Congurationchangehasoccurred
Thiserrormessageisdisplayedwhen
aharddiskdriveoropticaldrive
changehasbeenmade.
PressF10toexit.
0662
Congurationchangehasoccurred
Thiserrormessageisdisplayedwhen
aoppydrivechangehasbeenmade.
PressF10toexit.
1820
Morethanoneexternalngerprint
readerareattached.Poweroffand
removeallbutthereaderthatyouset
upwithinyourmainoperatingsystem.
Ifmorethanoneexternalngerprint
readerareconnectedtoacomputer,
thiserrormessagewillbedisplayed
toinformyoutoremoveallofthe
ngerprintkeyboardsexceptthe
onecompatiblewiththengerprint
applicationonyourcomputer.
1962
Nooperatingsystemfound.Press
anykeytorepeatbootsequence.
ThiserroroccursonlyafterthePOST
iscompleted.
Pressanykeytorepeatboot
sequence.
Miscellaneouserrorconditions
Message/SymptomFRU/Action
ChangingdisplaycolorsDisplay/Monitor
Computerwillnotpower-off.See“Harddiskdriveboot
error”onpage61.
1.PowerSwitch
2.SystemBoard
3.Risercard,ifinstalled.
ComputerwillnotRPLfromserver
1.Ensurethatnetworkisinstartupsequenceasrst
deviceorrstdeviceafterdiskette.
2.EnsurethatnetworkadapterisenabledforRPL.
3.Networkadapter(Advisenetworkadministratorof
newMACaddress)
80ThinkCentreEdgeHardwareMaintenanceManual