11.Dooneofthefollowing:
IfyouareinstallinganRDXdrive,savetheremovedEMI-protectiveshieldfromthechassisand
plasticshieldfromthefrontbezelintheeventthatyoulaterremovethedriveandneedtheshieldsto
coverthedrivebay.
IfyouarereplacinganRDXdriveandareinstructedtoreturntheoldRDXdrive,followallpackaging
instructionsanduseanypackagingmaterialsthataresuppliedtoyouforshipping.
Whattodonext:
Toworkwithanotherpieceofhardware,gototheappropriatesection.
Tocompletetheinstallationorreplacement,goto“Completingthepartsreplacement”onpage163.
Installingorreplacinga2.5-inchsolid-statedrive
Thistopiccontainsthefollowingitems:
“Installinga2.5-inchsolid-statedriveintoa3.5-inchhard-disk-drivebay”onpage108
“Replacinga2.5-inchsolid-statedrivefroma3.5-inchhard-disk-drivebay”onpage113
ForalistofThinkServersolid-statedriveoptions,goto:
http://www.lenovo.com/thinkserver
Youcaninstallorreplaceahot-swapsolid-statedrivewithoutturningofftheserver,whichhelpsyouavoid
significantinterruptiontotheoperationofthesystem.
TheEMIintegrityandcoolingoftheserverareprotectedbyhavingalldrivebayscoveredoroccupied.The
numberoftheinstalledharddiskdrivesorsolid-statedrivesinyourservervariesdependingontheserver
model.Thevacantbaysareoccupiedbydummyhard-disk-drivetrays.Whenyouinstallahot-swaphard
diskdriveorsolid-statedrive,savetheremoveddummyhard-disk-drivetrayfromthedrivebayinthe
eventthatyoulaterremovethehot-swapharddiskdriveorsolid-statedriveandneedthedummytrayto
covertheplace.
Attention:AnunoccupieddrivebaywithoutanyotherprotectionmightimpacttheEMIintegrityandcooling
oftheserver,whichmightresultinoverheatingorcomponentdamage.TomaintaintheEMIintegrityand
coolingoftheserver,installanewhot-swapharddiskdriveorsolid-statedriveassoonasyouremovethe
failingoneorthedummytray.
Beforeyoubegin,reviewthefollowingsolid-statedriveinstallationrules:
Followtheorderofthehard-disk-drivebayswheninstallingasolid-statedrive.See“Servercomponents”
onpage23
tolocatethehard-disk-drivebaysinyourserver.
ForRAIDconfiguration,thesolid-statedrivesmustbethesametypewiththesamecapacityiftheyare
withinasingleRAIDarray.Formoreinformation,see“ConfiguringRAID”onpage57.
Forsolid-statedriveswithdifferentcapacities,installthesolid-statedrivebyfollowingtheorderofthe
hard-disk-drivebaysaswellastheorderfromthelowestcapacitytothehighestcapacity.
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
computerforreference.
Notes:
Dependingonthemodel,yourservermightcomewith3.5-inchhot-swapharddiskdrivesor2.5-inch
hot-swapharddiskdrives.Theillustrationsinthistopicarebasedonservermodelswith3.5-inch
hot-swapharddiskdrives.Forothermodels,thereplacementprocedureissimilar.
Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationsinthistopic.
Chapter6.Installing,removing,orreplacinghardware107

Table of Contents