User Action:
1. Reseat SMM module.
2. If 1V2_SENSE warning is still asserted, replace SMM module.
0201071F: 1V15_SENSE: Voltage sensor, warning event was asserted, reading value %V (Threshold
%V)
Asserted when voltage sensed on 1.15V power rail is higher than high non-critical threshold.
Severity: Informational
User Action:
1. Reseat SMM module.
2. If 1V15_SENSE warning is still asserted, replace SMM module.
0201091A: 12V_SENSE: Voltage sensor, critical event was asserted, reading value %V (Threshold
%V)
Asserted when voltage sensed on 12V power rail is higher than upper critical threshold.
Severity: Critical
User Action:
1. Reseat SMM module.
2. If 12V_SENSE error is still asserted, replace SMM module.
0201091B: 3V3_SENSE: Voltage sensor, critical event was asserted, reading value %V (Threshold
%V)
Asserted when voltage sensed on 3.3V power rail is higher than upper critical threshold.
Severity: Critical
User Action:
1. Virtual reset SMM via Web GUI or IPMI command.
2. If 3V3_SENSE error is still asserted, replace SMM module.
0201091C: 5V_SENSE: Voltage sensor, critical event was asserted, reading value %V (Threshold %
V)
Asserted when voltage sensed on 5V power rail is higher than upper critical threshold.
Severity: Critical
User Action:
1. Reseat SMM module.
2. If 5V_SENSE error is still asserted, replace SMM module.
0201091D: 2V5_SENSE: Voltage sensor, critical event was asserted, reading value %V (Threshold
%V)
Asserted when voltage sensed on 2.5V power rail is higher than upper critical threshold.
Severity: Critical
User Action:
1. Reseat SMM module.
2. If 2V5_SENSE error is still asserted, replace SMM module.
0201091E: 1V2_SENSE: Voltage sensor, critical event was asserted, reading value %V (Threshold %